PARRIS ISLAND, SC —
OSHA Inspection: C & C BOILER SALES & SERVICE, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of C & C BOILER SALES & SERVICE, INC. in BUILDING #160 MCRD, PARRIS ISLAND, SC 29905 (NAICS 811310). OSHA activity number 339837122.
Where did this inspection happen?
- Establishment
- C & C BOILER SALES & SERVICE, INC.
- Site address
- BUILDING #160 MCRD
- City
- PARRIS ISLAND
- State
- SC
- ZIP
- 29905
- Mailing
- PO BOX 561745, CHARLOTTE, NC 28256
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.23 E09
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1910.23(e)(9): Wall opening barriers (rails, rollers, picket fences, and half doors) was of such construction and mounting that, when in place at the opening, the barrier was not capable of withstanding a load of at least 200 pounds applied in any direction (except upward) at any point on the top rail or corresponding member. a) Center of the 2nd floor of the Power Plant: A barrier placed in front of the 64-inch by 62-inch wall opening cut into the side of the Number-3 boiler was not secured to prevent workers from falling into the boiler. The barrier consisted of orange construction fencing which did not go the full width of the opening and a large piece of plywood which was simply leaned against the structure. ABATEMENT CERTIFICATION IS REQUIRED
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
More inspections at C & C BOILER SALES & SERVICE, INC.
COLUMBIA, SC—2013-09-26 00:00:00
C & C BOILER SALES & SERVICE INC
WILMINGTON, NC—2003-08-20 00:00:00
C&C BOILER SALES & SERVICE, INC.
View C & C BOILER SALES & SERVICE, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
CHRISTIANSBURG, VA—2026-07-09
BGIS GLOBAL INTEGRATED SOLUTION US, LLC
SEATTLE, WA—2026-07-09
WA317992010 - FLAGSHIP MANAGEMENT LLC
STATESBORO, GA—2026-07-08
TAYLOR BUILT PRODUCTS
, AK—2026-07-08
ANGUS ENTERPRISES
LOS ANGELES, CA—2026-07-08
CHILLEST INDUSTRIES LLC
More inspections in SC
CHARLESTON, SC—2026-07-15
U.S. DEPT OF TRANSPORTATION
COLUMBIA, SC—2026-07-15
77574 - PRECOAT METALS
NORTH CHARLESTON, SC—2026-07-14
DETYENS SHIPYARDS, INC.
GREENVILLE, SC—2026-07-09
77570 - SHARPSHOOTERS INDOOR RANGE INC
NORTH CHARLESTON, SC—2026-07-09
77569 - RAYCAP INC
Source