Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RIVERSIDE CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RIVERSIDE CONSTRUCTION in 859 VENABLE PL., NW, WASHINGTON, DC 20013 (NAICS 236118). OSHA activity number 339837320.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Riverside Construction — free Get an email when a new federal OSHA severe-injury report for Riverside Construction is published. One employer, no account, unsubscribe in one click.
Site address
859 VENABLE PL., NW
City
WASHINGTON
State
DC
ZIP
20013
Mailing
1725 FOREST GLEN DR., PRINCE FREDERICK, MD 20678
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
12
Ownership type
A

5 citations on file for this inspection.

1926.405 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2014
Abate by
Aug 19, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:   a)  Basement - On or about 06/03/2014, workers were exposed to a 120 volt electrical shock hazard from two wall-mounted duplex outlet box which had not been provided with a cover.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1600

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 30, 2014
Abate by
Aug 19, 2014
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  First Floor  On or about 06/03/2014, workers removing wood flooring were exposed to a 10 foot fall through four uncovered floor openings.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2400

1926.1053 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 30, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:   a)  First Floor - On or about 06/03/2014, workers were exposed to a 4 foot fall hazard from a 6 foot portable step ladder which projected only 18 in. above the ladder landing.
Recent events (1)
  • — Z (S) $1200

1926.1053 B04

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed:   A)  First Floor - On or about 06/03/2014, workers were exposed to a 4 foot fall hazard from a portable step ladder which had been left folded together and leaned up against the wall of a building and was used as the primary means of access to the buildings first floor.
Recent events (1)
  • — Z (S) $0

1926.404 B01 I

Other-than-serious 1 instance 2 exposed
Issued
Jul 30, 2014
Abate by
Aug 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction site:   Job Site - On or about 07/14/2014, workers using portable electric power tools, including, but not limited to, circular and reciprocating saws, were not provided with either ground fault circuit interrupters or an assured equipment grounding conductor program.
Recent events (1)
  • — Z (O) $0

View Riverside Construction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339837320.