WASHINGTON, DC —
OSHA Inspection: RIVERSIDE CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIVERSIDE CONSTRUCTION in 859 VENABLE PL., NW, WASHINGTON, DC 20013 (NAICS 236118). OSHA activity number 339837320.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIVERSIDE CONSTRUCTION
- Site address
- 859 VENABLE PL., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20013
- Mailing
- 1725 FOREST GLEN DR., PRINCE FREDERICK, MD 20678
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.405 B02
- Issued
- Jul 30, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) Basement - On or about 06/03/2014, workers were exposed to a 120 volt electrical shock hazard from two wall-mounted duplex outlet box which had not been provided with a cover. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $1600
1926.501 B13
- Issued
- Jul 30, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) First Floor On or about 06/03/2014, workers removing wood flooring were exposed to a 10 foot fall through four uncovered floor openings. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2400
1926.1053 B01
- Issued
- Jul 30, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a) First Floor - On or about 06/03/2014, workers were exposed to a 4 foot fall hazard from a 6 foot portable step ladder which projected only 18 in. above the ladder landing.
Recent events (1)
- — Z (S) $1200
1926.1053 B04
- Issued
- Jul 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed: A) First Floor - On or about 06/03/2014, workers were exposed to a 4 foot fall hazard from a portable step ladder which had been left folded together and leaned up against the wall of a building and was used as the primary means of access to the buildings first floor.
Recent events (1)
- — Z (S) $0
1926.404 B01 I
- Issued
- Jul 30, 2014
- Abate by
- Aug 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction site: Job Site - On or about 07/14/2014, workers using portable electric power tools, including, but not limited to, circular and reciprocating saws, were not provided with either ground fault circuit interrupters or an assured equipment grounding conductor program.
Recent events (1)
- — Z (O) $0
More inspections at Riverside Construction
View Riverside Construction's full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339837320.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.