KITTANNING, PA —
OSHA Inspection: ADVANCED PAINTING SYSTEMS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ADVANCED PAINTING SYSTEMS, INC. in KITTANNING CITIZENS BRIDGE, KITTANNING, PA 16201 (NAICS 238320). OSHA activity number 339838351.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED PAINTING SYSTEMS, INC.
- Site address
- KITTANNING CITIZENS BRIDGE
- City
- KITTANNING
- State
- PA
- ZIP
- 16201
- Mailing
- 2978 CLEARVIEW ROAD, ALLISON PARK, PA 15101
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 22
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.134 F02
- Issued
- Jul 16, 2014
- Abate by
- Aug 20, 2014
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1910.134(f)(2): The employer shall ensure that an employee using a tight-fitting facepiece respirator is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter: a) Kittanning Citizens Bridge, Kittanning, PA, on or about July 2, 2014 - The employer did not ensure that employees using a tight fitting full facepiece respirator were fit test prior to the use of that respirator. Employees were utilizing 3M 6899 B full face respirators during spraying operations and were not fit tested prior to the use of that respirator. b) Kittanning Citizens Bridge, Kittanning, PA, on or about July 2, 2014 - The employer did not ensure that employees were fit tested with the same respirator facepiece model that was used. An employee was utilizing a 3M 6200 respirator but was fit tested with a 3M 7500 series respirator.
Recent events (2)
- — I (S) $900
- — Z (S) $1200
More inspections at Advanced Painting Systems, INC.