On , OSHA opened a complaint health inspection of MARTINREA FABCO AUTOMOTIVE STRUCTURES (USA), INC. in 323 C D F BLVD, SHANNON, MS 38868 (NAICS 336370). OSHA activity number 339838930.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARTINREA FABCO AUTOMOTIVE STRUCTURES (USA), INC.
- Site address
- 323 C D F BLVD
- City
- SHANNON
- State
- MS
- ZIP
- 38868
- Mailing
- 323 C D F BLVD, SHANNON, MS 38868
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 86
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.217 H11 II
- Issued
- Oct 8, 2014
- Abate by
- Nov 26, 2014
- Penalty
- Initial $1,890 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(h)(11)(ii): At least annually thereafter, the safety system on a mechanical power press used in the PSDI mode shall be recertified by the employer and revalidated by an OSHA-recognized third-party validation organization to meet all applicable requirements of paragraphs (a) through (h) and Appendix A of this section. Any press whose safety system has not been recertified and revalidated within the preceding 12 months shall be removed from service in the PSDI mode until the safety system is recertified and revalidated: (a) Press Area - On or about August 13, 2014 the light curtains used to protect the employees from the point of operation had not been validated.
Recent events (2)
- — I (S) $0
- — Z (S) $1890
1910.303 G01 II
- Issued
- Oct 8, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $1,418 · Current $822 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Tool Room - On or about August 14, 2014 the electrical panel which powered the lights and other equipment in the area was blocked
Recent events (2)
- — I (S) $822.44
- — Z (S) $1418
1910.22 D01
- Issued
- Oct 8, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: (a) Tool Room - On or about August 14, 2014 there was material stored on top of the tool room office and there was not a load rating attached.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Martinrea Fabco Automotive Structures (USA), INC.
View Martinrea Fabco Automotive Structures (USA), INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336370)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339838930.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.