Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROCKLEDGE FURNITURE LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ROCKLEDGE FURNITURE LLC in 750 VETERANS PARKWAY, BOLINGBROOK, IL 60440 (NAICS 811420). OSHA activity number 339842023.

Watch Rockledge Furniture LLC — free Get an email when a new federal OSHA severe-injury report for Rockledge Furniture LLC is published. One employer, no account, unsubscribe in one click.
Site address
750 VETERANS PARKWAY
City
BOLINGBROOK
State
IL
ZIP
60440
Mailing
750 VETERANS PARKWAY, BOLINGBROOK, IL 60440
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811420
Employees
98
Ownership type
A

7 citations on file for this inspection.

1910.106 D04 I

Deleted Serious Gravity 1 1 instance 10 exposed
Issued
Nov 20, 2014
Abate by
Jan 9, 2015
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.106(d)(4)(i): "Construction." Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which drains to a safe location.   a.  On or about July 9, 2014, in the touch up and repair area, was an inside room used to store flammable liquids.  The room was not liquid tight or equipped with raised sills or trenches to contain or redirect flammable liquids in the event of flammable liquid leak.  The storage room was not equipped with a self closing fire door.  The lack of appropriate fire protection inside the flammable storage room exposed employees to hazards associated with fires.
Recent events (3)
  • — F (S) $0
  • — C (S) $3000
  • — Z (S) $3000

1910.106 D04 III

Deleted Serious Gravity 1 1 instance 10 exposed
Issued
Nov 20, 2014
Abate by
Jan 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(4)(iii): Wiring. Electrical wiring and equipment located in inside storage rooms used for flammable liquids, shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations;   a.  On or about July 9, 2014, in the touch up and repair area, was an inside flammable storage room used to store flammable liquids. The flammable storage room contained ordinary wiring and a gas fired hot water heater.  The inside storage room was not equipped with Class I, Division 2 rated electrical equipment thereby exposing employees to hazards associated with fires.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.106 D04 IV

Deleted Serious Gravity 1 1 instance 10 exposed
Issued
Nov 20, 2014
Abate by
Jan 9, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(4)(iv): Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour.  a.  On or about July 9, 2014, in the touch up and repair area, was an inside flammable storage room used to store flammable liquids.  The inside storage room was not equipped with a gravity or mechanical exhaust system.  The lack of exhaust provided for no air changes and thereby exposed employees to hazards associated with fires.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.132 D01

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2014
Abate by
Jan 9, 2015
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:   a.  On or about July 9, 2014, in the touch up and repair department, employees were required to work with chemicals including but not limited to, n-butyl acetate, toluene, and xylene.  The employer failed to perform an adequate hazard assessment for the work area to determine which hazards were present which necessitated the use of personal protective equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $4000
  • — Z (S) $4000

1910.132 F01

Other-than-serious 1 instance 10 exposed
Issued
Nov 20, 2014
Abate by
Jan 9, 2015
Penalty
Initial $0 · Current $4,000
29 CFR 1910.132(f)(1): The employer shall provide training to each employee who is required by this section to use PPE. Each such employee shall be trained to know at least the following:     a.  On or about July 9, 2014, in the facility, employees were not trained to know at least the following:     1.  What PPE is necessary.   2.  When PPE is necessary.   3.  How to properly don, doff, adjust and wear PPE.   4.  The limitations of PPE.   5.  The proper care, maintenance, useful life and disposal of PPE.     Employee exposure included but was not limited to n-butyl acetate, toluene, and xylene.
Recent events (3)
  • — F (O) $4000
  • — C (S) $0
  • — Z (S) $0

1910.107 B09

Other-than-serious 2 instances 10 exposed
Issued
Nov 20, 2014
Abate by
Dec 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.    a.  On or about July 9, 2014, in the touch up and repair area, employees sprayed flammable materials in a spray finishing booth.  Tables and storage cabinets were located adjacent and within three foot of the spray booth preventing employee access for proper cleaning.  Employees were thereby exposed to hazards associated with fires and explosions.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1052 D02

Other-than-serious 1 instance 10 exposed
Issued
Nov 20, 2014
Abate by
Jan 9, 2015
Penalty
Initial $1,000 · Current $0 Reduced

Hazardous substances 1730

29 CFR 1910.1052(d)(2): Initial determination. Each employer whose employees are exposed to MC shall perform initial exposure monitoring to determine each affected employee's exposure, except under the following conditions:    a.  On or about July 9, 2014, in the touch up and repair department, employees used material which contained methylene chloride to remove paint and stain and as a spray adhesive.  The employer failed to determine employee exposure to methylene chloride when performing required tasks.
Recent events (3)
  • — F (O) $0
  • — C (O) $1000
  • — Z (O) $1000

View Rockledge Furniture LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339842023.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.