LEHIGHTON, PA —
OSHA Inspection: SERVICE TEAM, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SERVICE TEAM, INC. in 6565 INTERCHANGE ROAD, LEHIGHTON, PA 18235 (NAICS 452990). OSHA activity number 339843732.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SERVICE TEAM, INC.
- Site address
- 6565 INTERCHANGE ROAD
- City
- LEHIGHTON
- State
- PA
- ZIP
- 18235
- Mailing
- 6565 INTERCHANGE ROAD, LEHIGHTON, PA 18235
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 452990
- Employees
- 74
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.305 B02 I
- Issued
- Dec 12, 2014
- Penalty
- Initial $1,785 · Current $1,339 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a) Wood Shop: The wall outlet behind the panel saw did not have a faceplate, exposing employees to a potential hazard, observed on or about July 25, 2014. CORRECTED DURING INSPECTION.
Recent events (2)
- — I (S) $1338.75
- — Z (S) $1785
1910.178 L06
- Issued
- Dec 12, 2014
- Abate by
- Dec 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. a) At 6565 Interchange Road, Lehighton, PA 18235: The employer's forklift certification did not include the identity of the person performing the training and evaluation nor the date of the evaluation, on or about July 25, 2014. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Dec 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Fish Department: A relocatable power tap (RPT) was hanging from an overhead light fixture and plugged into an extension cord, exposing employees to a potential electrical or fire hazard, observed on or about 7/25/14.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Service Team, INC.