OSHA Inspection: SUNG JIN CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNG JIN CONSTRUCTION INC. in 63 JOHN ST., ENGLEWOOD CLIFFS, NJ 07632 (NAICS 236118). OSHA activity number 339845737.

Watch Sung JIN Construction INC. — free Get an email when a new federal OSHA severe-injury report for Sung JIN Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
63 JOHN ST.
City
ENGLEWOOD CLIFFS
State
NJ
ZIP
07632
Mailing
14 SHERMAN AVE., CLOSTER, NJ 07624
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
A

9 citations on file for this inspection.

1926.95 A

Serious Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $1200.00 · Current $480.00 Reduced
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.      a) Front roof by garage right side: Employees without any eye protection were engaged in siding activities using a hand drill, on or about 5/31/2014.    b) Front of house: Employee without any eye protection was cutting wood with a circular saw, on or about 5/31/2014.
Recent events (3)
  • — F (S) $480
  • — C (S) $1200
  • — Z (S) $1200

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $1600.00 · Current $640.00 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:      a) Front of house: Employee was using an extension cord with a missing ground pin to power different electric power tools , on or about 5/31/2014.
Recent events (3)
  • — F (S) $640
  • — C (S) $1600
  • — Z (S) $1600

1926.405 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $1600.00 · Current $640.00 Reduced
29 CFR 1926.405(b)(2): In an energized installation, each outlet box did not have a cover, faceplate, or fixture canopy.      a) Garage wall: Employees were connecting an extension cord to a wall mounted outlet that did not have a face plate being exposed to electric shock, on or about 5/31/2014.    b) Garage ceiling: Employees were connecting an extension cord to a ceiling mounted outlet that did not have a face plate being exposed to electric shock, on or about 5/31/2014.
Recent events (3)
  • — F (S) $640
  • — C (S) $1600
  • — Z (S) $1600

1926.405 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1200.00 · Current $480.00 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:    a) Garage: Employee was powering an electric circular saw with a spliced extension cord being exposed to electric shock, on or about 5/31/2014.
Recent events (3)
  • — F (S) $480
  • — C (S) $1200
  • — Z (S) $1200

1926.451 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $800.00 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:        a) Pump Jack Scaffold - Front of House: The top triangle bracing pole clamp unit on both uprights was defective and could not be adjusted, requiring the use of wood wedges and exposing employees to a scaffold collapse, on or about 5/31/2014.
Recent events (3)
  • — F (S) $800
  • — C (S) $2000
  • — Z (S) $2000

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1120.00 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:      a) Pump Jack Scaffold - Front of House: Employees without any means of fall protection were engaged siding activities from a pump jack scaffold platform, being exposed to a fall of approximately 13 feet, on or about 5/31/2014.
Recent events (3)
  • — F (S) $1120
  • — C (S) $2800
  • — Z (S) $2800

1926.452 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2000.00 · Current $800.00 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.       a) Pump Jack Scaffold - Front of House: Employees were engaged in siding activities from a pump jack scaffold platform that was not secured at the bottom, being exposed to a scaffold collapse and consequent fall of approximately 13 feet, on or about 5/31/2014.
Recent events (3)
  • — F (S) $800
  • — C (S) $2000
  • — Z (S) $2000

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1600.00 · Current $640.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):       a) Front roof by garage right side: Employees without any means of fall protection were engaged in siding activities being exposed to a fall of approximately 14 feet, on or about 5/31/2104.
Recent events (3)
  • — F (S) $640
  • — C (S) $1600
  • — Z (S) $1600

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1120.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:     a) Scaffold by garage: Employees were accessing the scaffold over the garage doors with a ladder that did not extend 3 feet above the platform, being exposed to a fall of approximately 14 feet, on or about 5/31/2014.
Recent events (3)
  • — F (S) $1120
  • — C (S) $2800
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339845737.