GOODING, ID —
OSHA Inspection: GLANBIA FOODS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GLANBIA FOODS, INC. in 1734 S. 2300 E., GOODING, ID 83330 (NAICS 311513). OSHA activity number 339846446.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLANBIA FOODS, INC.
- Site address
- 1734 S. 2300 E.
- City
- GOODING
- State
- ID
- ZIP
- 83330
- Mailing
- 1734 S. 2300 E., GOODING, ID 83330
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311513
- Employees
- 370
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.119 D03 II
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $7,000 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices. (a) Rooftop relieve valves: On or about July 7, 2014 and at times prior thereto, the employer did not document that relief venting for equipment complied with RAGAGEP in that, the relief vents were not 15 feet about the adjacent grade or roof level. Ammonia equipment includes, but is not limited to, EV-1; EV-2 and EV-3. (b) Site ammonia system: On or about July 7, 2014 and at times prior thereto, the employer did not document that ammonia refrigeration system piping and components were properly identified. Ammonia equipment with missing tags includes, but is not limited to, the HX-1 (three valves) and EV-1; EV-2 and EV3. (c) Site ammonia system: On or about July 7, 2014 and at times prior thereto, the employer did not document that the ceiling and door openings for the machinery room had tight fittings to the outside. The ceiling/wall opening were visible; the overhead door on the south end of the machine room, and man doors on the SW and SE sides of the room were blocked open by water hoses. Note: Abatement certification AND documentation is required for this item.
Recent events (2)
- — I (S) $4000
- — Z (S) $7000
1910.119 N
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $4,250 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.119(n): The employer did not establish and implement an emergency plan for the entire plant in accordance with the provisions of 29 CFR 1910.38: (a) Gooding Site main office: On or about July 7, 2014 and at times prior thereto, from approximately 1:30-1:50 pm, emergency radios were not activated in response to a power outage. (b) Gooding Site main office: On or about July 7, 2014 and at times prior thereto, emergency exit lighting was not illuminated with emergency power in response to power outage. (c) Gooding Site facility, Emergency Action Plan: On or about July 7, 2014 and at times prior thereto, the emergency responder list had not been kept up to date. (d) Gooding Site facility, Emergency Action Plan: On or about July 7, 2014 and at times prior thereto, the ammonia monitoring action levels were not consistent throughout the plan, nor were they linked to the evacuation levels. Note:
Recent events (2)
- — I (S) $2200
- — Z (S) $4250
1910.119 O04
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(o)(4): The employer did not promptly determine and document an appropriate response to each of the findings of the compliance audit, and document that deficiencies had been corrected. (a) Gooding Site: On or about July 7, 2014 and at times prior thereto, the compliance audit recommendation for improving emergency response procedures was not addressed. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C02
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $200 · Current $150 Reduced
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: (a) Steam Vault: On or about July 7, 2014 and at times prior thereto an uncovered vault did not have a sign posted at or near the permit-required confined space to inform employees of the potential danger and prohibit unauthorized entry. Note: Abatement certification AND documentaion is required for this item.
Recent events (2)
- — I (O) $150
- — Z (R) $200
1910.23 C01
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. (a)Cheese Plant Roof Top: On or about July 7, 2014 and at times prior thereto, the employer did not provide fall protection for the raised ledge (54 inches) above the adjacent roof level. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.146 C05 II B
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(B): When an entrance cover was removed, the opening was not promptly guarded by a railing, temporary cover, or other temporary barrier that would prevent an accidental fall through the opening and that would protect each employee. (a)Steam Vault: On or about July 7, 2014 and at times prior thereto the cover to a confined space vault with a leak was left open. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G01
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. (a) Machinery Room: On or about July 7, 2014 and at times prior thereto, an SDS (safety data sheet) for Ammonia was not available for the employees working in and around the ammonia machinery room. Note: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Glanbia Foods, INC.
View Glanbia Foods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311513)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339846446.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.