Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: QUANTEM AVIATION SERVICES, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUANTEM AVIATION SERVICES, LLC in 14700 TERMINAL BLVD, CLEARWATER, FL 33762 (NAICS 488119). OSHA activity number 339848202.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quantem Aviation Services, LLC for free Get an email when a new federal OSHA severe-injury report for Quantem Aviation Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
14700 TERMINAL BLVD
City
CLEARWATER
State
FL
ZIP
33762
Mailing
14695 TERMINAL BLVD SUITE 205, CLEARWATER, FL 33762
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488119
Employees
55
Ownership type
Private (A)

2 citations on file for this inspection.

1910.141 B01 I

Other-than-serious 1 instance 36 exposed
Issued
Jul 18, 2014
Abate by
Aug 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal service rooms:  (a) on the ramp - facilities for hand washing was not available for up to 36 male employees; observed on or about 7/15/14.
Recent events (1)
  • · Z (O) $0

1910.141 C01 I

Other-than-serious 1 instance 36 exposed
Issued
Jul 18, 2014
Abate by
Aug 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(c)(1)(i): Toilet facilities were not provided in accordance with TABLE J-1 of this Section which requires a minimum of 3 water closets for 36 to 55 employees:  (a) on the ramp - one portable toilet facility was provided for the use of up to 36 male employees; observed on or about 7/15/14.
Recent events (1)
  • · Z (O) $0

View Quantem Aviation Services, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339848202.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.