Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: CITY AUTO PLAZA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CITY AUTO PLAZA in 3151 E. HWY 50, CANON CITY, CO 81212 (NAICS 441110). OSHA activity number 339848210.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch City Auto Plaza for free Get an email when a new federal OSHA severe-injury report for City Auto Plaza is published. One employer, no account, unsubscribe in one click.
Establishment
CITY AUTO PLAZA
Site address
3151 E. HWY 50
City
CANON CITY
State
CO
ZIP
81212
Mailing
3151 E. HWY 50, CANON CITY, CO 81212
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
31
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 16, 2014
Abate by
Oct 10, 2014
Penalty
Initial $2,550 · Current $1,275 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing and stuck-by hazards:  (a)  On or about July 10, 2014, and at times prior, the employer did ensure that the Kar Grabber G-Force Frame Rack was inspected by a qualified inspector at least annually to ensure that it was properly maintained and functioning.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1275
  • · Z (S) $2550

1910.1200 F05 I

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 16, 2014
Abate by
Sep 24, 2014
Penalty
Initial $3,400 · Current $1,700 Reduced
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    (a)  On or about July 10, 2014, the employer did not ensure employees were aware of the contents of a spray bottle with a purple solution that was unlabeled in the tire balancing area.    (b)  On or about July 10, 2014, and at times prior, the employer did not ensure employees were aware of the contents of two unlabeled containers in the paint mixing room, one is a black barrel used for cleaning spray guns, and the other is a waste water container.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $1700
  • · Z (S) $3400

1910.134 H01 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 16, 2014
Abate by
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(1)(i): Respirators issued for the exclusive use of an employee were not cleaned and disinfected as often as necessary to be maintained in a sanitary condition:  (a)  On or about July 10, 2014, the employer did not ensure that an employee was protected from contaminants that were inside the respirator that he wore during automotive painting operations.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 B07 IV

Other-than-serious 1 instance 8 exposed
Issued
Sep 16, 2014
Abate by
Sep 24, 2014
Penalty
Initial $850 · Current $425 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of electric equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action, or overheating:    (a)  On or about March 10, 2014, and at times prior, the employer did not ensure that employees were protected from electrical hazards from an outlet affixed to the exterior wall next to the Quick Lube bay doors which had a broken and deteriorated covers.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $425
  • · Z (O) $850

1910.305 J02 VII

Other-than-serious 1 instance 2 exposed
Issued
Sep 16, 2014
Abate by
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(j)(2)(vii):  A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed:  (a)  On or about July 10, 2014, and at times prior, the employer did not ensure that employees were protected from electrical hazards in the car wash where a plug on the north wall at the west end did not have a cover that closed completely allowing water and other contaminants to enter the outlet.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339848210.