Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GENERAL COMPOSITES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GENERAL COMPOSITES, INC. in 39 MEYERS WAY, WILLSBORO, NY 12996 (NAICS 326199). OSHA activity number 339849325.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch General Composites, INC. — free Get an email when a new federal OSHA severe-injury report for General Composites, INC. is published. One employer, no account, unsubscribe in one click.
Site address
39 MEYERS WAY
City
WILLSBORO
State
NY
ZIP
12996
Mailing
39 MEYERS WAY, WILLSBORO, NY 12996
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 22, 2014
Abate by
Oct 9, 2014
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Shop Floor - On or prior to July 14, 2014, employees were exposed to caught between hazards when operating and working around the "Granite Gear Machine" (Tag: GCi LQP0637) without adequate machine guarding.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3500

1910.303 B02

Serious Gravity 1 3 instances 3 exposed
Issued
Aug 22, 2014
Abate by
Oct 9, 2014
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Shop Floor near entrance - On or about July 14, 2014, a multiple receptacle electrical outlet box meant for mounting on the wall was used for pendant application power access.  b) Shop Floor - On or about July 14, 2014, a multiple receptacle electrical outlet box meant for mounting on the wall was used for pendant application power access.  c) Shop Floor near bucket - On or about July 14, 2014, a multiple receptacle electrical outlet box meant for mounting on the wall was used for pendant application power access.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 22, 2014
Abate by
Oct 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) Shop Floor near entrance - On or about July 14, 2014, a multiple receptacle electrical outlet box with visible insulation damage to the cord was in use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View General Composites, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339849325.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.