Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUBURBAN OIL SERVICE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUBURBAN OIL SERVICE in 109 ALDEN RD., NANTICOKE, PA 18634 (NAICS 454310). OSHA activity number 339849804.

Watch Suburban OIL Service — free Get an email when a new federal OSHA severe-injury report for Suburban OIL Service is published. One employer, no account, unsubscribe in one click.
Site address
109 ALDEN RD.
City
NANTICOKE
State
PA
ZIP
18634
Mailing
109 ALDEN RD., NANTICOKE, PA 18634
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
454310
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2000.00 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors:    a) Outside Suburban Oil Service, Nanticoke, PA: Adequate precautions were not taken to prevent ignition of flammable vapors while employees attempt to conduct welding on fuel delivery tank trucks, exposing employees to potential injuries, on or about July 9, 2014.    Abatement Certification Required.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1910.252 A02 XIII A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.252(a)(2)(xiii)(A): The employer did not recognize its responsibility for the safe usage of cutting or welding equipment, based on fire potentials of plant facilities, and establish areas for cutting and welding, and procedures for cutting and welding, in other areas:  a) Outside Suburban Oil Service, Nanticoke, PA: The employer did not develop procedures for welding and cutting on fuel tanks while employees weld on fuel delivery tank trucks, exposing employees to potential injuries, on or about July 9, 2014.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 C04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:  a) Outside Suburban Oil Service, Nanticoke, PA: The employer did not develop and implement a written permit space entry program for employees entering fuel delivery truck tanks, on or about July 9, 2014.  Abatement Certification Required.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339849804.