VICTOR, NY —
OSHA Inspection: ADVANCED INTERCONNECT MANUFACTURING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED INTERCONNECT MANUFACTURING in 780 CANNING PARKWAY, VICTOR, NY 14564 (NAICS 336320). OSHA activity number 339850117.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED INTERCONNECT MANUFACTURING
- Site address
- 780 CANNING PARKWAY
- City
- VICTOR
- State
- NY
- ZIP
- 14564
- Mailing
- 780 CANNING PARKWAY, VICTOR, NY 14564
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336320
- Employees
- 61
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 22, 2014
- Abate by
- Aug 24, 2014
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Warehouse Area, on or about 7/15/14: Bridgeport milling machine was not equipped with a guard to prevent contact with the serrated chuck and cutting tool. b) Maintenance, on or about 7/15/14: Delta single spindle drill press was not equipped with a guard to prevent contact with the serrated chuck and cutting tool.
Recent events (2)
- — I (S) $1428
- — Z (S) $2380
1910.303 B02
- Issued
- Jul 22, 2014
- Abate by
- Sep 19, 2014
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Throughout the facility, on or about 7/15/14: Pendant cords with metal receptacle boxes attached were used to provide power to various equipment. These metal boxes are listed for permanent mounting only.