BLACK, MO ·
OSHA Inspection: BELL MOUNTAIN LUMBER PRODUCTS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BELL MOUNTAIN LUMBER PRODUCTS in 23252 HIGHWAY 49, BLACK, MO 63625 (NAICS 321113). OSHA activity number 339850307.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELL MOUNTAIN LUMBER PRODUCTS
- Site address
- 23252 HIGHWAY 49
- City
- BLACK
- State
- MO
- ZIP
- 63625
- Mailing
- 23252 HIGHWAY 49, BLACK, MO 63625
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.178 P01
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a. The Kobelco loader was operated with brakes that were not fully functional. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $840
- · Z (S) $1200
1910.303 G02 I
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a. By the cut off saw, 120 V conductors were exposed; wire nuts capped the conductors. b. Openings existed in a circuit breaker box by the head saw. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $840
- · Z (S) $1200
1910.303 B02
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. A light switch knockout box was not mounted, but was hanging by Romex. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B07 IV
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of electric equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action, or overheating: a. A light switch faceplate was broken with exposed conductors. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 B01 I
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a. There was no protection from abrasion to the conductor entering an outlet (by the edger). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G02 III
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a. Strain relief was lacking for the power cord to the cooling fan motor by the edger. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.304 A02
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.304(a)(2): Grounded conductors were attached to terminals or leads so as to reverse designated polarity: a. By the cut off saw, 120 V outlet, used to power equipment such as a fan, was wired with reverse polarity. b. By the head saw, 120 V outlet, used to power equipment such as a blade sharpener, was wired with reverse polarity. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)
- · I (S) $840
- · Z (S) $1200
1910.304 G05
- Issued
- Aug 15, 2014
- Abate by
- Oct 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. By the cut off saw, a 120 V cooling fan was used with a missing ground pin. b. By the edger saw, 120 V outlet, used to power equipment such as a cooling fan, was not grounded (open ground). Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (2)