Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RESTEEL SUPPLY CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RESTEEL SUPPLY CORPORATION in 2001 ST. FERDINAND ST., NEW ORLEANS, LA 70177 (NAICS 332312). OSHA activity number 339850398.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Resteel Supply Corporation — free Get an email when a new federal OSHA severe-injury report for Resteel Supply Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2001 ST. FERDINAND ST.
City
NEW ORLEANS
State
LA
ZIP
70177
Mailing
2001 ST. FERDINAND ST., NEW ORLEANS, LA 70177
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.212 A05

Serious Gravity 10 3 instances 4 exposed
Issued
Jul 29, 2014
Abate by
Aug 11, 2014
Penalty
Initial $2,800 · Current $700 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:  On or about May 15, 2014, at the center of the jobsite, the employer allowed employees to utilize three (3) fans (blowers), in order to stay cool, which were not guarded.
Recent events (2)
  • — I (S) $700
  • — Z (S) $2800

1910.303 B07 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 29, 2014
Abate by
Aug 11, 2014
Penalty
Initial $1,600 · Current $400 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of electric equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action, or overheating:  On or about May 15, 2014, at the center of the jobsite, the employer allowed employees to utilize a rebar bender (Arnold Bender), which had a broken on/off switch box.
Recent events (2)
  • — I (S) $400
  • — Z (S) $1600

1910.305 G02 II

Other-than-serious 3 instances 4 exposed
Issued
Jul 29, 2014
Abate by
Aug 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  On or about May 15, 2014, at the center of the jobsite, the employer allowed employees to utilize three (3) fans (blowers), in order to stay cool, which had cords that were not adequately spliced.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Resteel Supply Corporation's full OSHA safety record →