WILKES BARRE, PA ·
OSHA Inspection: THE LION BREWERY INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE LION BREWERY INC. in 700 NORTH PENNSYLVANIA AVENUE, WILKES BARRE, PA 18705 (NAICS 312120). OSHA activity number 339851586.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE LION BREWERY INC.
- Site address
- 700 NORTH PENNSYLVANIA AVENUE
- City
- WILKES BARRE
- State
- PA
- ZIP
- 18705
- Mailing
- 350 LAIRD STREET, WILKES BARRE, PA 18702
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312120
- Employees
- 145
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 9, 2015
- Abate by
- Dec 31, 2015
- Penalty
- Initial $2,295 · Current $1,400 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to chemical burns and inhalation hazards from ammonia: Ammonia refrigeration system: The machinery room was not provided with approved self closing labeled fire doors, restricted access, visual/audible alarms outside of each entrance door and emergency remote controls for ventilation and to stop the action of the refrigerating compressors immediately outside the machinery room, on or about July 16, 2014. Ammonia refrigeration system: All piping mains, headers and branches throughout the facility were not identified as to the physical state of the refrigerant (vapor, liquid, etc.), on or about July 16, 2014. Abatement Certification Required.
Recent events (2)
- · I (S) $1400
- · Z (S) $2295
1910.134 E01
- Issued
- Jan 9, 2015
- Abate by
- May 27, 2015
- Penalty
- Initial $3,060 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Maintenance: The employer did not provide a medical evaluation to determine the employee's ability to use full face air purifying respirators or self contained breathing apparatus (SCBA), on or about July 16, 2014. Abatement Certification Required.
Recent events (2)
- · I (S) $1800
- · Z (S) $3060
1910.134 F02
- Issued
- Jan 9, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: a) Maintenance: Employees using full face air purifying respirators and self contained breathing apparatus (SCBA) were not annually fit tested, on or about July 16, 2014. Abatement Certification Required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 H03 III
- Issued
- Jan 9, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(3)(iii): Self-contained breathing apparatus was not inspected monthly: a) Brew house: The two Scott self contained breathing apparatus (SCBA) were not inspected on a monthly basis, on or about July 16, 2014. Abatement Certification Required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 K05
- Issued
- Jan 9, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(5): Respiratory protection retraining was not conducted annually: a) Brew house: Employees did not receive annual retraining on respiratory protection, on or about July 16, 2014. Abatement Certification Required.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.120 Q01
- Issued
- Jan 9, 2015
- Abate by
- Feb 27, 2015
- Penalty
- Initial $2,295 · Current $1,390 Reduced
General-duty citation text
29 CFR 1910.120(q)(1): The employer, who would evacuate employees from the danger area when an emergency occurred and would not permit any employees to assist in handling the emergency, did not provide an emergency action plan in accordance with 1910.38: a) Brew house: The employer did not review the emergency action plan with employees covered when the employee's responsibilities under the plan changed and/or when the plan changed in that employees responded to an ammonia release without proper emergency response training, on or about July 16, 2014. Abatement Certification Required.
Recent events (2)
- · I (S) $1390
- · Z (S) $2295
More inspections at The Lion Brewery INC.
View The Lion Brewery INC.'s full OSHA safety record →
More inspections in this industry (NAICS 312120)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339851586.