FULTON, MO —
OSHA Inspection: MISSOURI FABRICATORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MISSOURI FABRICATORS in 3200 COUNTY ROAD 257, FULTON, MO 65251 (NAICS 332312). OSHA activity number 339853319.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MISSOURI FABRICATORS
- Site address
- 3200 COUNTY ROAD 257
- City
- FULTON
- State
- MO
- ZIP
- 65251
- Mailing
- 3200 COUNTY ROAD 257, FULTON, MO 65251
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 75
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.23 E01
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing did not consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level: a/ Inside of the Fabrication Shop, the stairrail belonging to a metal flight of stairs consisting of 14 risers was missing a mid-rail. b/ Inside of the Receiving Department, two, metal flights of stairs consisting of five risers were missing a standard railing.
Recent events (2)
- — I (S) $2300
- — Z (S) $3500
1910.147 C04 I
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a/ Inside of the Fabrication Shop, specific lockout/tagout procedures were not developed in writing for the Controlled Automation Drill, m/n DR1-340, s/n 98-06. This machine utilizes 480 volts, 80 p.s.i. hydraulic, and 60 p.si.. pneumatic.
Recent events (2)
- — I (S) $2300
- — Z (S) $3500
1910.147 C04 II
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not provide a means to enforce compliance. a/ The written lockout/tagout program did not include a means of enforcing compliance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: a/ Inside of the Fabrication Shop, periodic audits of the specific lockout/tagout procedures were not performed for machinery such as the Controlled Automation Drill, m/n DR1-340, s/n 98-06. This machine utilizes 480 volts, 80 p.s.i. hydraulic, and 60 p.si.. pneumatic.
Recent events (2)
- — I (S) $2300
- — Z (S) $3500
1910.147 C07 I A
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: Inside of the Fabrication Shop, the authorized employee was not trained in the following: a/ That a written energy isolation procedure was required for the Controlled Automation Drill, m/n DR1-340, s/n 98-06. b/ That periodic audits of the energy isolation procedure for the Controlled Automation Drill, m/n DR1-340, s/n 98-06, were required to be performed. c/ That the hydraulic and pneumatic energy sources were required to be isolated prior to servicing the Controlled Automation Drill, m/n DR1-340, s/n 98-06.
Recent events (2)
- — I (S) $2300
- — Z (S) $3500
1910.147 D03
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a/ Inside of the Fabrication Shop, the hydraulic and pneumatic energy isolation devices belonging to the Controlled Automation Drill, m/n DR1-340, s/n 98-06, were not operated prior to servicing.
Recent events (2)
- — I (S) $2300
- — Z (S) $3500
1910.212 A01
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $2,300 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Inside of the Cutting Department, the chuck and unused portion of the drill bit belonging to the following machines were unguarded: a/ IKEDA Radial Arm Drill, m/n 78307, s/n RM-1300. b/ Brown & Sharpe Milling Machine, s/n 51731375.
Recent events (2)
- — I (S) $2300
- — Z (S) $3500
1910.212 A03 II
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation (P.O.O.) guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a/ Inside of the Cutting Department, the P.O.O. belonging to the GEKA Ironworker, Hydrocrop 110A, was inadequately guarded. The specific P.O.O. include the punch and flat shearing station.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a/ Inside of the Fabrication Shop, the orange, flexible cord used by an employee to power a Milwaukee Portable Hand Grinder, m/n C98C14060768, s/n 6121-31A, was missing its ground pin.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1910.334 A02 II
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: Inside of the Fabrication Shop, the outer insulation belonging to the following flexible cords was damaged: a/ The orange, flexible cord used by an employee to power a ilwaukee Portable Hand Grinder, m/n C98C14060768, s/n 6121-31A. b/ The yellow, flexible cord used by an employee to power a E-2 Arm Flow Systems Inc. Inside of the Cutting Department, the outer insulation belonging to the following flexible cords was damaged: a/ The black, flexible cord used by an employee to cycle a GEKA Ironworker, Hydrocrop 110A.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jul 23, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a/ Inside of the Fabrication Shop, adjacent to column 34, two receptacles were missing from a metallic, quad-receptacle box.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
More inspections at Missouri Fabricators
View Missouri Fabricators's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339853319.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.