OSHA Inspection: UNCLE LUKE'S ROOFING AND SIDING

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of UNCLE LUKE'S ROOFING AND SIDING in WASHINGTON MANOR APARTMENTS, 505 WASHINGTON STREET, WATERTOWN, NY 13601 (NAICS 238160). OSHA activity number 339854374.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Uncle Luke'S Roofing and Siding — free Get an email when a new federal OSHA severe-injury report for Uncle Luke'S Roofing and Siding is published. One employer, no account, unsubscribe in one click.
Site address
WASHINGTON MANOR APARTMENTS, 505 WASHINGTON STREET
City
WATERTOWN
State
NY
ZIP
13601
Mailing
23268 KNOWLSVILLE ROAD, WATERTOWN, NY 13601
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 2 exposed
Issued
Dec 18, 2014
Abate by
Jan 8, 2015
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) At the jobsite, on or about 12/18/2014:  The employer did not provide abatement certification for Citation 1, Items 001a, 001b, 002a, and 002b issued on August 4, 2014.  An abatement demand letter was sent to the employer on October 30, 2014.    Abatement certification is required for this item.
Recent events (1)
  • — Z (O) $400

1926.501 B10

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 4, 2014
Abate by
Aug 12, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:  a)  At the jobsite, on the roof, on or about 7/16/14:  Employees were working on a low slope roof, with an approximate ground to eave height of 30 feet, without fall protection.    Abatement documentation must be submitted for this item.
Recent events (1)
  • — Z (S) $2800

1926.503 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 4, 2014
Abate by
Sep 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a)  At the jobsite, on the roof, on or about 7/16/14:  Employees were working on a low slope roof, with an approximate ground to eave height of 30 feet, without fall protection.    Abatement documentation must be submitted for this item.
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 4, 2014
Abate by
Aug 12, 2014
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a)  At the jobsite, accessing the roof from inside the building, on or about 7/16/14:  Employees were using a step ladder which was collapsed and leaned against a wall to access an opening on the roof that was approximately 3 feet above the top level of that ladder.   Abatement documentation must be submitted for this item.
Recent events (1)
  • — Z (S) $2400

1926.1060 A

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 4, 2014
Abate by
Sep 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:  a)  At the jobsite, accessing the roof from inside the building, on or about 7/16/14:  Employees were using a step ladder which was collapsed and leaned against a wall to access an opening on the roof that was approximately 3 feet above the top level of that ladder and without being trained on safe use of ladders.   Abatement documentation must be submitted for this item.