Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GORSAL STUCCO DESIGN INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GORSAL STUCCO DESIGN INC. in 380 BELLEVILLE PIKE, NORTH ARLINGTON, NJ 07031 (NAICS 238140). OSHA activity number 339855215.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gorsal Stucco Design INC. — free Get an email when a new federal OSHA severe-injury report for Gorsal Stucco Design INC. is published. One employer, no account, unsubscribe in one click.
Site address
380 BELLEVILLE PIKE
City
NORTH ARLINGTON
State
NJ
ZIP
07031
Mailing
75 HAWKINS ST, NEWARK, NJ 07105
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.451 C02

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 2, 2014
Penalty
Initial $1,320 · Current $264 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:        a) Scaffold on Roof perpendicular to Elm St.: Employees were engaged in stucco activities from a one frame high welded tubular scaffold that had missing base plates exposing employees to scaffold collapse and fall hazard of approximately 6 feet, on or about 4/3/2014.
Recent events (3)
  • — F (S) $264
  • — C (S) $1320
  • — Z (S) $1320

1926.451 G01

Serious Gravity 10 2 instances 1 exposed
Issued
Oct 2, 2014
Penalty
Initial $3,080 · Current $616 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.         a) Scaffold on building exterior on Elm St.: Employee without an acceptable means of fall protection was engaged in stucco activities from a 4 frame high welded tubular scaffold, being exposed to a fall hazard of approximately 24 feet onto a concrete sidewalk, on or about 4/3/2014.    b) Scaffold on building exterior on Elm St.: Employee without an acceptable means of fall protection was engaged in stucco activities from a pump jack scaffold platform, being exposed to a fall hazard of approximately 24 feet onto a concrete sidewalk, on or about 4/3/2014.
Recent events (3)
  • — F (S) $616
  • — C (S) $3080
  • — Z (S) $3080

1926.501 B04 I

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 2, 2014
Penalty
Initial $1,760 · Current $352 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around them:      a) Roof perpendicular to Elm St.: Employees were working on roof with unprotected skylights, being exposed to a fall hazard of approximately 12 feet, on or about 4/3/2014.
Recent events (3)
  • — F (S) $352
  • — C (S) $1760
  • — Z (S) $1760

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 2, 2014
Penalty
Initial $2,200 · Current $440 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      a) Building exterior, access to roof from Elm St.: Employees were accessing the roof using the upper section of an extension ladder in the upside down position that did not extend at least 3 feet above the platform, being exposed to a fall hazard of approximately 12 feet, on or about 4/3/2014.
Recent events (3)
  • — F (S) $440
  • — C (S) $2200
  • — Z (S) $2200

1926.1053 B04

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 2, 2014
Penalty
Initial $2,200 · Current $440 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a) Access by Elm St.: Employees were accessing the roof using the upper section of an extension ladder in the upside down position, being exposed to a fall hazard of approximately 12 feet, on or about 4/3/2014.
Recent events (3)
  • — F (S) $440
  • — C (S) $2200
  • — Z (S) $2200

1926.451 E01

Willful Gravity 5 1 instance 1 exposed
Issued
Oct 2, 2014
Penalty
Initial $24,200 · Current $5,728 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.      a) Scaffold on roof by Elm St: Employee engaged in stucco activities was using the crossbraces while accessing a 2 frame high  tubular scaffold without the use of a ladder, being exposed to a fall hazard of approximately 12 feet, on or about 4/3/2014.
Recent events (3)
  • — F (W) $5728
  • — C (W) $24200
  • — Z (W) $24200

1926.451 F06

Willful Gravity 10 3 instances 3 exposed
Issued
Oct 2, 2014
Penalty
Initial $30,800 · Current $7,160 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).    Less Than 300 V - minimum distance required - 3 feet  Between 300 V and 50 KV - minimum distance required - 10 feet      a) Scaffold on Elm St.: Employee engaged in stucco activities from a 4 frame high tubular welded scaffold approximately 5 feet away form the 13KV Primary was exposed to an electrocution hazard, on or about 4/3/2014.    b) Scaffold on Elm St.: Employee engaged in stucco activities from a pump jack scaffold touching the 240V secondary was exposed to an electrocution hazard, on or about 4/3/2014.    c) Scaffold on the roof.: Employee engaged in stucco activities from a 1 frame high tubular welded scaffold approximately 1 foot from the 240V secondary was exposed to an electrocution hazard, on or about 4/3/2014.
Recent events (3)
  • — F (W) $7160
  • — C (W) $30800
  • — Z (W) $30800

View Gorsal Stucco Design INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339855215.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.