SANTA ROSA BEACH, FL ·
OSHA Inspection: CARING AND SHARING OF SOUTH WALTON COUNTY, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of CARING AND SHARING OF SOUTH WALTON COUNTY, INC. in 112 LYNN DRIVE, SANTA ROSA BEACH, FL 32459 (NAICS 453310). OSHA activity number 339855405.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARING AND SHARING OF SOUTH WALTON COUNTY, INC.
- Site address
- 112 LYNN DRIVE
- City
- SANTA ROSA BEACH
- State
- FL
- ZIP
- 32459
- Mailing
- PO BOX 2122, SANTA ROSA BEACH, FL 32459
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 453310
- Employees
- 8
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1910.37 A03
- Issued
- Oct 22, 2014
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a. On or about July 17, 2014, upstairs in the lady's department, the exit route was blocked by an obstruction in the route, exposing employees to tripping and fire hazards. b. On or about July 17, 2014, in the warehouse, the exit route was obstructed in the route, exposing employees to tripping and fire hazards.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.304 G05
- Issued
- Oct 22, 2014
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. On or about July 17, 2014, in the warehouse on the southwest side, the employer did not ensure a flexible cord used to power a wall light and an overhead florescent light had a continuous ground, exposing employees to a fire and an electrical hazard.
Recent events (2)
- · I (S) $2940
- · Z (S) $4900
1910.305 B01 I
- Issued
- Oct 22, 2014
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed: a. On or about July 17, 2014, upstairs in the lady's department, the main panel box was missing a knockout, exposing employees to an electrical hazard. b. On or about July 17, 2014, in the warehouse, the receptacle light switch box was missing a knockout, exposing employees to an electrical hazard.
Recent events (2)
- · I (S) $2100
- · Z (S) $3500
1910.305 G01 IV A
- Issued
- Oct 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. On or about July 17, 2014, in the warehouse on the southwest side, employees used flexible cords as permanent wiring to power a small refrigerator, exposing employees to a fire and electrical hazard. b. On or about July 17, 2014, in the warehouse on the southwest side, employees used flexible cords as permanent wiring to power a overhead florescent light, exposing employees to a fire and electrical hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV B
- Issued
- Oct 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Temporary wiring was running through holes in walls, ceilings, or floors: a. On or about July 17, 2014, in the warehouse on the southwest side, employees used temporary cords that were placed through holes in walls, exposing employees to fire and electrical hazards. b. On or about July 17, 2014, in the warehouse on the southwest side, employees used temporary cords that were placed through doors, exposing employees to fire and electrical hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G02 II
- Issued
- Oct 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a. On or about July 17, 2014, in the warehouse on the southwest side, the employer did not ensure flexible cords to power a light fixture was used without splices, exposing employees to a fire and electrical hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.22 D01
- Issued
- Oct 22, 2014
- Abate by
- Nov 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: a. On or about July 17, 2014, in the sales area inside the front entry door on the north side, the area above the preparation room, was not load tested to show the capacity of the floor, exposing employees to crushing hazards. b. On or about July 17, 2014, in the sales area above shelving units on the south side , storing items, was not load tested to show the capacity of the floor, exposing employees to crushing hazards. c. On or about July 17, 2014, in the warehouse area, the area above the library, storing items, was not load tested to show the capacity of the floor, exposing employees to crushing hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 E01
- Issued
- Oct 22, 2014
- Abate by
- Nov 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about July 17, 2014, the employer did not maintain a written hazard communication program.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 H01
- Issued
- Oct 22, 2014
- Abate by
- Nov 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
1910.1200(h)(1): Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment: a. On or about July 17, 2014, in the warehouse, the employer did not inform employees on the hazardous chemicals used in the workplaces, exposing employees to skin, eye, and inhalation hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Caring and Sharing of South Walton County, INC.
View Caring and Sharing of South Walton County, INC.'s full OSHA safety record →