PLEASANTON, TX ·
OSHA Inspection: RIVERSIDE ELECTRONICS INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RIVERSIDE ELECTRONICS INC in M.M. 102 N. IH 37 28.887202, -98.404640, PLEASANTON, TX 78064 (NAICS 541850). OSHA activity number 339856031.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIVERSIDE ELECTRONICS INC
- Site address
- M.M. 102 N. IH 37 28.887202, -98.404640
- City
- PLEASANTON
- State
- TX
- ZIP
- 78064
- Mailing
- P.O. BOX 1510, FORT WORTH, TX 76101
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541850
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1412 E01
- Issued
- Sep 30, 2014
- Abate by
- Oct 4, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.1412(e)(1): 29 CFR 1926.1412(e)(1): The equipment in service was not inspected each month in accordance with paragraph (d) of this section (each shift): On or about July 16, 2014, employees were exposed to struck-by hazards when a Pioneer mobile crane model X4000-RCC, serial #44007990421, was used when no monthly inspections were performed, while lifting the column of an outdoor advertisement billboard.
Recent events (1)
- · Z (S) $2800
1926.1412 F01
- Issued
- Sep 30, 2014
- Abate by
- Oct 4, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.1412(f)(1): 29 CFR 1926.1412(f)(1): The equipment was not inspected at least every 12 months by a qualified person in accordance with paragraph (d) of this section: On or about July 16, 2014, employees were exposed to struck-by hazards, when a Pioneer crane model #X4000-RCC, serial #44079904211, was used when no annual inspection was preformed, while lifting the column of an outdoor advertisement billboard.
Recent events (1)
- · Z (S) $2800
1926.1413 B01
- Issued
- Sep 30, 2014
- Abate by
- Oct 4, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.1413(b)(1): Monthly wire rope inspections were not performed in accordance with paragraph (a) or documented according to 1926.1412(e)(3). On or about July 16, 2014, employees were exposed to struck-by hazards, when a Pioneer crane model #X4000-RCC, serial #44079904211, was used when no wire rope inspections were preformed, while lifting the column of an outdoor advertisement billboard.
Recent events (1)
- · Z (S) $2800