DAYVILLE, CT ·
OSHA Inspection: ALES RENOVATION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALES RENOVATION, LLC in 485 HARTFORD PIKE, DAYVILLE, CT 06241 (NAICS 238160). OSHA activity number 339856403.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALES RENOVATION, LLC
- Site address
- 485 HARTFORD PIKE
- City
- DAYVILLE
- State
- CT
- ZIP
- 06241
- Mailing
- 321 MAIN STREET, FARMINGTON, CT 06032
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.252 A
- Issued
- Aug 18, 2014
- Penalty
- Initial $1,320 · Current $660 Reduced
General-duty citation text
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s): Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut: On, or about, July 18, 2014, a chute had not been provided where roofing debris was thrown down from a flat roof to a dumpster below.
Recent events (2)
- · I (S) $660
- · Z (S) $1320
1926.403 B02
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $2,200 · Current $1,100 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut: On, or about, July 18, 2014, a relocatable power tap that was not listed or labeled for use on construction sites was used to energize two extension cords and a battery charging unit.
Recent events (2)
- · I (S) $1100
- · Z (S) $2200
1926.404 F06
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut: On, or about, July 18, 2014, a relocatable power tap used to energize two extension cords and a battery charging unit appeared to be damaged and did not provide a path to ground on the equipment grounding conductor when tested.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.404 B01 II
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $1,760 · Current $880 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut: On, or about, July 18, 2014, the ground fault circuit interrupter receptacle that was being used to energize equipment on the jobsite did not trip when subjected to an external test.
Recent events (2)
- · I (S) $880
- · Z (S) $1760
1926.416 E01
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut: On, or about, July 18, 2014, an extension cord used to energize a Ridgid R6000 portable screwdriver was damaged in several locations.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B10
- Issued
- Aug 18, 2014
- Abate by
- Oct 3, 2014
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut: On, or about, July 18, 2014, neither fall protection systems nor personal fall arrest/restraint equipment had been provided to employees engaged in roofing work. Employees were exposed to a fall of approximately twenty feet, one inch to the ground below.
Recent events (2)
- · I (S) $1540
- · Z (S) $3080
More inspections at Ales Renovation, LLC
View Ales Renovation, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339856403.