OSHA Inspection: ALES RENOVATION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALES RENOVATION, LLC in 485 HARTFORD PIKE, DAYVILLE, CT 06241 (NAICS 238160). OSHA activity number 339856403.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ales Renovation, LLC for free Get an email when a new federal OSHA severe-injury report for Ales Renovation, LLC is published. One employer, no account, unsubscribe in one click.
Site address
485 HARTFORD PIKE
City
DAYVILLE
State
CT
ZIP
06241
Mailing
321 MAIN STREET, FARMINGTON, CT 06032
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.252 A

Serious Gravity 1 1 instance 3 exposed
Issued
Aug 18, 2014
Penalty
Initial $1,320 · Current $660 Reduced
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s):   Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut:  On, or about, July 18, 2014, a chute had not been provided where roofing debris was thrown down from a flat roof to a dumpster below.
Recent events (2)
  • · I (S) $660
  • · Z (S) $1320

1926.403 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 18, 2014
Abate by
Oct 3, 2014
Penalty
Initial $2,200 · Current $1,100 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:   Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut:  On, or about, July 18, 2014, a relocatable power tap that was not listed or labeled for use on construction sites was used to energize two extension cords and a battery charging unit.
Recent events (2)
  • · I (S) $1100
  • · Z (S) $2200

1926.404 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 18, 2014
Abate by
Oct 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut:  On, or about, July 18, 2014, a relocatable power tap used to energize two extension cords and a battery charging unit appeared to be damaged and did not provide a path to ground on the equipment grounding conductor when tested.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 18, 2014
Abate by
Oct 3, 2014
Penalty
Initial $1,760 · Current $880 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:   Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut:  On, or about, July 18, 2014, the ground fault circuit interrupter receptacle that was being used to energize equipment on the jobsite did not trip when subjected to an external test.
Recent events (2)
  • · I (S) $880
  • · Z (S) $1760

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 18, 2014
Abate by
Oct 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut:  On, or about, July 18, 2014, an extension cord used to energize a Ridgid R6000 portable screwdriver was damaged in several locations.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 18, 2014
Abate by
Oct 3, 2014
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:  Jobsite located at 485 Hartford Pike, Route 101, Dayville, Connecticut:  On, or about, July 18, 2014, neither fall protection systems nor personal fall arrest/restraint equipment had been provided to employees engaged in roofing work.  Employees were exposed to a fall of approximately twenty feet, one inch to the ground below.
Recent events (2)
  • · I (S) $1540
  • · Z (S) $3080

View Ales Renovation, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339856403.