OSHA Inspection: SOUTHERN ROOFING

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of SOUTHERN ROOFING in 3610 BRYAN STREET, DALLAS, TX 75204 (NAICS 238160). OSHA activity number 339856676.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southern Roofing — free Get an email when a new federal OSHA severe-injury report for Southern Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
SOUTHERN ROOFING
Site address
3610 BRYAN STREET
City
DALLAS
State
TX
ZIP
75204
Mailing
6913 AVENUE K SUITE 315, PLANO, TX 75074
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
20
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 28, 2014
Abate by
Sep 10, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer did not develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502:  This violation was most recently observed on July 16, 2014, at the job site located at 3610 Bryan Street, Dallas, Texas 75204; where employees were exposed to fall hazards while working more than 6-feet above the ground level below without the use of a guardrail system or personal fall arrest system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800