Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUPERIOR BUILDERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUPERIOR BUILDERS, INC. in 801 ZEREX ST, FRASER, CO 80442 (NAICS 236220). OSHA activity number 339858243.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Superior Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
801 ZEREX ST
City
FRASER
State
CO
ZIP
80442
Mailing
PO BOX 968, LIMON, CO 80828
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 23, 2014
Abate by
Aug 18, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface having an unprotected side or edge which was 6 feet or more above a lower level was not protected from falling by the use of a guardrail system, a safety net system, or personal fall arrest system.      (a)Superior Builders, Inc. at 801 Zerex St, Fraser, CO 80442:  On and before July 11, 2014, the controlling employer did not ensure that subcontractor employees on a walking/working surface having an unprotected side or edge which was six feet or more above a lower level were protected from falling by the use of a guardrail system, a safety net system, or personal fall arrest system, in that, subcontractor employees waterproofed first and second level balcony decks without fall protection.  This condition exposed subcontractor employees to fall hazards of approximately 10 and 20 feet.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B11

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 23, 2014
Abate by
Aug 18, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(11):  Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.      (a)Superior Builders, Inc. at 801 Zerex St, Fraser, CO 80442:  On and before July 11, 2014, the controlling employer did not ensure that subcontractor employees were protected from injury, in that, subcontractor employees installing shingles on the roof of a three-story building, with a roof pitch of 5-in-12, were not utilizing a fall protection system.  This condition exposed subcontractor employees to a fall hazard of approximately 30 feet.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View Superior Builders, INC.'s full OSHA safety record →