WASHINGTON, DC —
OSHA Inspection: ALL PHASE DRYWALL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALL PHASE DRYWALL, INC. in 1625 14TH. ST., NW, WASHINGTON, DC 20009 (NAICS 238310). OSHA activity number 339862302.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL PHASE DRYWALL, INC.
- Site address
- 1625 14TH. ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 10665 STAHAVEN PL., SUITE 106A, WHITE PLAINS, MD 20695
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 10
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.302 E01
- Issued
- Sep 30, 2014
- Abate by
- Oct 18, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.302(e)(1): Powder actuated tool(s) were operated by employee(s) who had not been trained in the operation of the particular tool(s) in use: a) Roof, Elevator Control Room - On or about 07/21/2014, a drywall mechanic was operating a Ramset powder-actuated tool while constructing a steel stud framed wall and had not been properly trained in the operation of the particular tool. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.302 E05
- Issued
- Sep 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.302(e)(5): Tools (loaded or empty) were pointed at an employee: a) Roof, Elevator Control Room - On or about 07/21/2014, a drywall mechanic was operating a Ramset powder-actuated tool fired the loaded tool in his own direction while installing while a steel stud framed wall .
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.302 E12
- Issued
- Sep 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.302(e)(12): Powder-actuated tools used by employees shall meet all other applicable requirements of American National Standards Institute, A10.3-1970, Safety Requirements for Explosive-Actuated Fastening Tools: a) Roof, Elevator Control Room - On or about 07/21/2014, a drywall mechanic was operating a Ramset powder-actuated tool while constructing a steel stud framed wall left the tool unattended in the work area while at lunch in violation of American National Standards Institute, A10.3-1970, Safety Requirements for Explosive Actuated Fastening Tools, A10.3.6.7.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01
- Issued
- Sep 30, 2014
- Abate by
- Oct 18, 2014
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) Roof, Elevator Control Room - On or about 07/17/2014, a drywall mechanic was working from the platform of a welded metal frame scaffold whose platform was not fully planked. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1926.501 B01
- Issued
- Sep 30, 2014
- Abate by
- Oct 18, 2014
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) Roof, Elevator Control Room - On or about 07/17/2014, drywall mechanics were exposed to a 60 foot fall from the unprotected edge of a flat roof while accessing a ladder used to reach their work area. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $3500
1926.1053 B01
- Issued
- Sep 30, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a) Roof, Elevator Control Room - On or about 07/21/2014, drywall mechanics were exposed to a 10 foot fall from a 10 foot portable step ladder which did not extend three feet above the ladder landing and which was not secured in place and provided with a grab rail.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B04
- Issued
- Sep 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Roof - Elevator Control Room - On or about 07/21/2014, drywall mechanics were exposed to a 10 foot fall while climbing a 10 foot fiberglass portable step ladder which was left folded together and leaned up against a wall while in use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ALL Phase Drywall, INC.
View ALL Phase Drywall, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339862302.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.