SAINT PETERS, MO —
OSHA Inspection: ARROWHEAD BUILDING SUPPLY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARROWHEAD BUILDING SUPPLY in 13 GUENTHER BLVD., SAINT PETERS, MO 63376 (NAICS 423330). OSHA activity number 339862559.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARROWHEAD BUILDING SUPPLY
- Site address
- 13 GUENTHER BLVD.
- City
- SAINT PETERS
- State
- MO
- ZIP
- 63376
- Mailing
- 13 GUENTHER BLVD., SAINT PETERS, MO 63376
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423330
- Employees
- 120
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 D01
- Issued
- Aug 11, 2014
- Abate by
- Sep 26, 2014
- Penalty
- Initial $2,295 · Current $2,295
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate: In the shop above the office, for employee(s) who access overhead storage, a load limit plate was not present.
Recent events (2)
- — I (S) $2295
- — Z (S) $2295
1910.23 C01
- Issued
- Aug 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: a/ Siding warehouse, for employee(s) who access the overhead storage area approximately 3-4 times per week to obtain materials, the overhead storage area was missing a guardrail for approximately 25 feet. The fall distance was approximately 10 feet. b/ Shop, for employee(s) who access the overhead storage area above the office, the overhead storage area was missing a guard rail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 I
- Issued
- Aug 11, 2014
- Abate by
- Sep 26, 2014
- Penalty
- Initial $2,295 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware was not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: For authorized employee(s) who performed servicing or maintenance on the compressor, a circuit breaker lock was not provided to lock out the circuit breaker servicing the compressor.
Recent events (2)
- — I (S) $0
- — Z (S) $2295
1910.147 C07 I
- Issued
- Aug 11, 2014
- Abate by
- Sep 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees: For authorized employee(s) who performed servicing or maintenance on the compressor, lockout tag out training had not been conducted.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Aug 11, 2014
- Abate by
- Sep 26, 2014
- Penalty
- Initial $2,295 · Current $1,836 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts: In the shop the GRIZZLY Mid Americal Peterbilt Model G1006 drill press used approximately every other day was missing a chuck guard.
Recent events (2)
- — I (S) $1836
- — Z (S) $2295
1910.215 A04
- Issued
- Aug 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): On offhand grinding machines, work rest(s) were not adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage: In the shop, the opening between the work rest and the periphery of the abrasive wheel, belonging to the 23-880 8" Delta bench grinder, measured 1/2 inch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Aug 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceeded one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.) In the shop, the opening between the tongue guard and the periphery of the abrasive wheel, belonging to the 23-880 8" Delta bench grinder, measured 1/2 inch.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Aug 11, 2014
- Abate by
- Nov 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): In any workplace where respirators are necessary to protect the health of the employee or whenever respirators are required by the employer, the employer did not establish and implement a written respiratory protection program including but not limited to a written program, medical evaluation, fit testing, and training. In the shop for employee(s) who were required to use 1/2 face negative pressure respirators with OV cartridges and P95 filters to spray paint indoors in the winter, a respiratory protection program had not been implemented.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Arrowhead Building Supply
View Arrowhead Building Supply's full OSHA safety record →
More inspections in this industry (NAICS 423330)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339862559.