On , OSHA opened a complaint health inspection of CENTRAL ARKANSAS VETERANS HEALTHCARE SYSTEM in 4300 WEST 7TH STREET, LITTLE ROCK, AR 72205 (NAICS 561730). OSHA activity number 339864209.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Central Arkansas Veterans Healthcare System — free Get an email when a new federal OSHA severe-injury report for Central Arkansas Veterans Healthcare System is published. One employer, no account, unsubscribe in one click.
Site address
4300 WEST 7TH STREET
City
LITTLE ROCK
State
AR
ZIP
72205
Mailing
4300 WEST 7TH STREET, LITTLE ROCK, AR 72205
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
7
Ownership type
D

8 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.   On or about July 24, 2014 and at times prior thereto, at the groundskeeper's office in a modular building, the employer did not ensure the inside of the building was maintained in a sanitary condition. Employees working in the groundskeeper's office are exposed to visible mold, mildew and water damage on the walls, ceilings and window sills. This condition exposes employees to biological hazards associated with the growth of mold.
Recent events (1)
  • — Z (S) $0

1910.22 A03

Serious Gravity 1 1 instance 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(3): Every floor, working place, and passageway was not kept free from protruding nails, splinters, holes, or loose boards:    On or about July 24, 2014 and at times prior thereto, at the groundskeeper's office in a modular building, the employer did not ensure the Vinyl Composition Tile (VCT) flooring and entry threshold was maintained inside of the building. Upon entering the building, the threshold is loose and bent upward and floor tiles are broken and missing throughout the building. This condition exposes employees to trip and fall hazards associated with the loose and missing floor components.
Recent events (1)
  • — Z (S) $0

1910.23 A10

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(a)(10): A platform was not provided where door(s) or gate(s) opened directly on a stairway:   On or about July 24, 2014 and at times prior thereto, at the groundskeeper's office in a modular building, the employer did not provide a platform where the door open on to the wooden steps. This condition exposed employees to trip and fall hazards during access and egress of the building.
Recent events (1)
  • — Z (S) $0

1910.23 E03 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types were not of such construction that the completed structure was not capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail:    On July 24, 2014 and at times thereto, at the groundskeeper's office in a modular building, the employer did not ensure the supplied railing on the wood steps was anchored to the building and capable of withstanding an applied load.  Upon load being applied, the rails begin to sway side-to-side. This condition exposed employees to fall hazards at heights greater than 2 feet to the ground below.
Recent events (1)
  • — Z (S) $0

1910.23 E05 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(5)(i): Handrail(s) did not consist of a lengthwise member that was mounted directly on a wall or partition by means of a bracket attached to the lower side of the handrail:   On July 24, 2014 and at times thereto, at the groundskeeper's office in a modular building, the employer supplied handrail attached to the wooden steps was not mounted to a wall or partition. This condition exposed employees to fall hazards at heights greater than 2 feet to the ground below.
Recent events (1)
  • — Z (S) $0

1910.36 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency.   On or about July 24, 2014 and at times prior thereto, at the groundskeeper's office in a modular building, the employer did not ensure at least two exit routes were available to employees. One of the two exits to the groundskeeper's office building had a piece of plywood which covered the entire door opening. This condition created delay in exiting the building in an emergency, and trip and fall hazards in a fire.
Recent events (1)
  • — Z (S) $0

1910.305 G01 III

Serious Gravity 5 2 instances 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iii):   If used as permitted in paragraphs (g)(1)(ii)(C), (g)(1)(ii)(G), or (g)(1)(ii)(I) of this section, the flexible cord shall be equipped with an attachment plug and shall be energized from an approved receptacle outlet.  On or about July 24, 2014 and at times prior thereto, at the Groundskeeper's office located in a modular building, the employer allowed the use of a temporary flexible cord to be used as a substitute for the fixed wiring of the structure. Employees were using a surge protector extension cord to power electrical equipment.   This condition exposed employees to electrical shock and/or burn and fire hazards.
Recent events (1)
  • — Z (S) $0

1910.141 B01 I

Other-than-serious 1 instance 3 exposed
Issued
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(b)(1)(i): Potable water was not provided in all places of employment, for drinking, washing of the person, cooking, washing of foods, washing of cooking or eating utensils, washing of food preparation or processing premises, and personal service rooms:   On or about July 24, 2014 and at times prior thereto, at the groundskeeper's office in a modular building, the employer did not provide employees with potable water.  There is no running water in the lavatory and a tan, sponge-like mold is growing from the faucet of the lavatory sink.