CARROLLTON, GA —
OSHA Inspection: DIXIE CONVERTING CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIXIE CONVERTING CORPORATION in 889 BLANDENBURG ROAD, CARROLLTON, GA 30116 (NAICS 322299). OSHA activity number 339864845.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIXIE CONVERTING CORPORATION
- Site address
- 889 BLANDENBURG ROAD
- City
- CARROLLTON
- State
- GA
- ZIP
- 30116
- Mailing
- 889 BLANDENBURG ROAD, CARROLLTON, GA 30116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Records only (C)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322299
- Employees
- 71
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Sep 26, 2014
- Abate by
- Oct 6, 2014
- Penalty
- Initial $3,850 · Current $2,310 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) The production areas of the facility. There was not a periodic, at least annual, inspection of the Lockout/Tagout (LOTO) program and procedures to ensure the control of energy during servicing or maintenance of equipment.
Recent events (2)
- — I (S) $2310
- — Z (S) $3850
1910.147 C07 I B
- Issued
- Sep 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) The production areas of the facility. Without proper training and instruction employees, who are affected by Lockout/Tagout procedures, could attempt to restart or reenergize machines or equipment which has been locked out for maintenance or repair.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Dixie Converting Corporation
View Dixie Converting Corporation's full OSHA safety record →
More inspections in this industry (NAICS 322299)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339864845.