OSHA Inspection: WESTERN REFINING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WESTERN REFINING in 6501 TROWBRIDGE, EL PASO, TX 79905 (NAICS 324110). OSHA activity number 339865248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Western Refining — free Get an email when a new federal OSHA severe-injury report for Western Refining is published. One employer, no account, unsubscribe in one click.
Establishment
WESTERN REFINING
Site address
6501 TROWBRIDGE
City
EL PASO
State
TX
ZIP
79905
Mailing
212 N. CLARK DRIVE, EL PASO, TX 79905
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
Employees
340
Ownership type
A

3 citations on file for this inspection.

1910.147 D03

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 18, 2014
Abate by
Jan 8, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source.    Vacuum Tower Unit:  On or about July 23, 2014, an employee failed to ensure through the use of a rod-out tool that an isolation valve was sufficiently closed to isolate the equipment from the energy source.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 D05 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 18, 2014
Abate by
Jan 8, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:  Vacuum Tower Unit:  On or about July 23, 2014, the employer did not ensure all potentially hazardous stored or residual energy was relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices while replacing a control valve.  Employees were exposed to inhalation, fire, and burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.147 D06

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Dec 18, 2014
Abate by
Jan 8, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  Vacuum Tower Unit:  On or about July 23, 2014, the employer did not ensure that prior to starting work on equipment that had been locked out, the authorized employee verified that isolation and deenergization of the equipment had been accomplished.  Employees were exposed to inhalation, fire, and burn hazards while replacing a control valve.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

View Western Refining's full OSHA safety record →