OSHA Inspection: GUHRING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GUHRING, INC. in 1455 NORTH BARKER ROAD, BROOKFIELD, WI 53045 (NAICS 333515). OSHA activity number 339874505.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Guhring, INC. — free Get an email when a new federal OSHA severe-injury report for Guhring, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GUHRING, INC.
Site address
1455 NORTH BARKER ROAD
City
BROOKFIELD
State
WI
ZIP
53045
Mailing
1455 COMMERCE AVENUE PO BOX 643, BROOKFIELD, WI 53008
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333515
Employees
270
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 3, 2014
Abate by
Dec 30, 2014
Penalty
Initial $4,000 · Current $2,600 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:    (a)  The employer did not ensure employees who accessed the top of the Transor Oil Filter System to check Freon levels in the Frigadon refrigeration unit were protected from falling 79 inches to the lower level.
Recent events (2)
  • — I (S) $2600
  • — Z (S) $4000

1910.147 C04 II

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 3, 2014
Penalty
Initial $7,000 · Current $4,550 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section:    (a)  The employer did not ensure that the energy control procedures for equipment, such as but not limited to the Transor Oil Filtration System, contained the specific steps for de-energization and verification of lockout devices.
Recent events (2)
  • — I (S) $4550
  • — Z (S) $7000

1910.147 C06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   (a)  A periodic inspection of the energy control procedures was not conducted to ensure compliance with the standard was accomplished and skill proficiency with lockout was maintained when performing maintenance and servicing on equipment (e.g. Transor Oil Filtration System).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A05

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 3, 2014
Penalty
Initial $7,000 · Current $4,550 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    (a) On or about July 25, 2014, the employer did not ensure employee(s) working on the Transor filter system, including the Frigadon refrigeration panel, was isolated from the energy source(s) prior to performing maintenance and/or servicing work.
Recent events (2)
  • — I (S) $4550
  • — Z (S) $7000

1910.1030 C01 IV

Other-than-serious 1 instance 24 exposed
Issued
Dec 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually:  (a) The employer did not ensure their Exposure Control Plan was reviewed and updated on an annual basis.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Guhring, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339874505.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.