Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OLUWOLE OKE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OLUWOLE OKE in 5310 - 5316 BASS PLACE, SE, WASHINGTON, DC 20019 (NAICS 236116). OSHA activity number 339876351.

Watch Oluwole OKE — free Get an email when a new federal OSHA severe-injury report for Oluwole OKE is published. One employer, no account, unsubscribe in one click.
Establishment
OLUWOLE OKE
Site address
5310 - 5316 BASS PLACE, SE
City
WASHINGTON
State
DC
ZIP
20019
Mailing
327 ANACOSTIA STREET, SE K21, WASHINGTON, DC 20019
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
7
Ownership type
A

9 citations on file for this inspection.

1926.25 A

Serious Gravity 5 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.25(a): During the course of construction, alteration, or repairs,  debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:  (a) Building 5316 - Workers were observed conducting framing work and their working areas and passageways were heavily cluttered with debris some which contained protruding nails, on or about July 31, 2014.  (b) Building 5314 - Workers were observed conducting framing work and their working areas and passageways were heavily cluttered with debris some which contained protruding nails, on or about July 31, 2014.  (c) Building 5312 - Workers were observed conducting framing work and their working areas and passageways were heavily cluttered with debris some which contained protruding nails, on or about July 31, 2014.  (d) Building 5310 - Workers were observed conducting framing work and their working areas and passageways were heavily cluttered with debris some of which contained protruding nails and one portion had two protruding metal pipes sticking up creating an impalement hazard, on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1600

1926.150 C01 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof):  (a)  Buildings 5310 to 5316 - Workers were conducting framing work throughout four 3 story buildings and no fire extinguisher was provided on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1200

1926.152 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.152(a)(1): Containers and portable tanks used for the storage and handling of flammable and combustible liquids were not approved:  (a)  Building 5314 - Employees were using a gas container that was missing its spout cover to replenish fuel in their generators on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $1200

1926.501 B13

Serious Gravity 10 5 instances 5 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a)  Building 5316 Rooftop - Workers were conducting framing work and were exposed to a 30 feet 3 inches fall hazard without using fall protection, on or about July 31, 2014.  (b)  Building 5316 3rd Floor to 1st floor - Workers were conducting framing work and were exposed to a 20 feet 10 inches fall hazard through a floor opening, without using fall protection, on or about July 31,2014.   (c)  Building 5316 2nd Floor to 1st floor - Workers were conducting framing work and were exposed to a 10 feet 5 inches fall hazard through a floor opening without using fall protection, on or about July 31,2014.   (d)  Buildings 5310 - 5316 - Workers were conducting framing work without using fall protection in areas that had unguarded window openings with ledges that were 2 feet above the floor and were exposed to a 13 feet 3 inches to a 22 feet 11 inches fall hazard, on or about July 31, 2014.   (e)  Building 5310 3rd Floor- Workers were conducting framing work in an area that had an unguarded stairway opening and were exposed to a 10 feet 5 inches fall hazard without using fall protection, on or about July 31,2014.      Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2800

1926.1053 A02

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(a)(2): Ladder rungs, cleats, and/or steps were not parallel, level, and uniformly spaced when the ladder was in position for use:    (a)  Building 5316 - Workers were using a  job made ladder to access their work area that had ladder rungs that were spaced  between 10 inches to 14 inches apart and the workers were exposed to a 10 feet 5 inches fall hazard onto a concrete floor, on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $2000

1926.1053 A13

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(a)(13): The perpendicular clearance between fixed ladder rungs, cleats, and steps, and any obstruction behind the ladder was less than 7 inches (18 cm):   (a)  Building 5316 - Workers were using a fixed ladder mounted a wall to access their work area and its rungs were approximately 5 inches away from the wall and the workers were exposed to a 20 feet 10 inches fall hazard onto a concrete floor, on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.1053 B16

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  (a)  Building 5316 - Workers were using a ladder to access their work area that had split rungs and was not tagged as "Do Not Use" and the workers were exposed to a 10 feet 5 inches fall hazard onto a concrete floor, on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.1052 C01 I

Other-than-serious 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  (a)  Building 5312 - Workers was constructing a stairway with four risers and it did not have a handrail, on or about July 31, 2014.  (b)  Building 5310 - Workers were using a stairway with twelve risers to access their work area on the upper floors and it did not have a handrail, on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (O) $0

1926.1052 C01 II

Other-than-serious 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  (a)  Building 5312 - Workers was constructing a stairway with four risers and it did not have a stairrail  system, on or about July 31, 2014.  (b)  Building 5310 - Workers were using a stairway with twelve risers to assess their work area on the upper floors and it did not have a stairrail system, on or about July 31, 2014.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (O) $0