Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KENDALL PACKAGING CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KENDALL PACKAGING CORPORATION in 1901 E 27TH TERRACE, PITTSBURG, KS 66762 (NAICS 322221). OSHA activity number 339876682.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kendall Packaging Corporation — free Get an email when a new federal OSHA severe-injury report for Kendall Packaging Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1901 E 27TH TERRACE
City
PITTSBURG
State
KS
ZIP
66762
Mailing
1901 E 27TH TERRACE, PITTSBURG, KS 66762
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322221
Employees
51
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II D

Serious Gravity 1 7 instances 10 exposed
Issued
Sep 3, 2014
Abate by
Sep 29, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control:  In the production area, equipment lockout/tagout procedures were missing the required step to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control, exposing employees to caught in and struck by hazards in the following instances:      1) REMCO Lathe     2) W&H     3) SR8 Titan      4) DEACRO Rewinder     5) Schiavi Eco Junior     6) Vision II     7) SR7 Titan
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.159 C10

Serious Gravity 1 2 instances 5 exposed
Issued
Sep 3, 2014
Abate by
Sep 29, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained:  Automatic water sprinkler heads were obstructed in two different location, exposing employees to burns from fire.  1)  In the Pre-Press area, a water sprinkler head mounted on the stairway leading to the overhead plate storage area was blocked by a stack of papers resting on a file cabinet located approximately 5 inches below the sprinkler head.  2) In the Overhead Plate Storage Area, cardboard boxes, which contained printing plates were stored within approximately 10 inches from water sprinkler heads.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.305 G01 IV A

Serious Gravity 1 1 instance 20 exposed
Issued
Sep 3, 2014
Abate by
Sep 29, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  In the break room, a flexible cords, which was plugged into a 110 VAC electrical outlet, was being used to power a multi-receptacle extension cord, which had a flexible cable running to a cabinet mounted electrical outlet, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 3, 2014
Abate by
Sep 29, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  In the forklift charging area, the Powerhouse Charger has cabling that had pulled from the attachment plug, exposing bare copper on one of the leads, resulting in an electrical shock hazard for employees.
Recent events (2)
  • — I (S) $1249.5
  • — Z (S) $1785

View Kendall Packaging Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339876682.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.