PECOS, TX ·
OSHA Inspection: AQUILA SEDCO DRILLING COMPANY, LP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AQUILA SEDCO DRILLING COMPANY, LP in REEVES 2723 LEASE, WELL #2SWD, RIG 3, 3 MILES N OF PECOS, TX, PECOS, TX 79772 (NAICS 213111). OSHA activity number 339877557.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AQUILA SEDCO DRILLING COMPANY, LP
- Site address
- REEVES 2723 LEASE, WELL #2SWD, RIG 3, 3 MILES N OF PECOS, TX
- City
- PECOS
- State
- TX
- ZIP
- 79772
- Mailing
- 2525 KELL BLVD., SUITE 405, WICHITA FALLS, TX 76308
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 92
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.303 G01 VII B
- Issued
- Oct 29, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.303(g)(1)(vii)(B): The employer did not ensure that outdoor electrical equipment was protected from accidental contact by vehicular traffic. Drill Site: On or about July 29, 2014, and at times prior thereto, the employer did not protect the 480 volt 8/4 AWG flexible cords extending from the transformer to the drilling rig from damage caused by vehicles. This condition exposed the employees to electrical hazards.
Recent events (1)
- · Z (S) $3500
1910.305 A02 X
- Issued
- Oct 29, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: On or about July 29, 2014, and at times prior thereto, The 240 volt 8/4 AWG flexible cord running from one side of the change house to the other was not protected when going through unprotected wall openings. This condition exposed the employees to an electrical hazard.
Recent events (1)
- · Z (S) $3500
1910.305 G01 I
- Issued
- Oct 29, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $3,500 · Current $3,500
General-duty citation text
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location: Drill site: On or about July 29, 2014, and at times prior thereto, the employer had the crew use a wall mounted electrical connection to connect two 480 volt 8/4 AWG flexible cords together, to feed power to the drilling rig approximately 200-feet from the transformer. This condition exposed the employees to an electrical hazard.
Recent events (1)
- · Z (S) $3500
1910.305 G02 III
- Issued
- Oct 29, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Drill Site: On or about July 29, 2014, the strain relief to the outlet hanging outside the change house by the door was damaged. This condition exposed the employees to electrical hazards.
Recent events (1)
- · Z (S) $2800
1910.334 A02 I
- Issued
- Oct 29, 2014
- Abate by
- Nov 4, 2014
- Penalty
- Initial $5,600 · Current $5,600
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): Drill site: On or about July 29, 2014, and at times prior thereto, the employer failed to inspect the 480 volt 8/4 AWG flexible cord for damage prior to use. The flexible cord stretched from the transformer across 200-feet to the drilling rig while maintenance was performed. This condition exposed the employees to electrical hazards. The Aquila Drilling Co., LP was previously cited for a violation of this occupational safety and health standard 1910.334(a)(2)(I), which was contained in OSHA inspection number 313502536, citation number 1, item number 4 and was affirmed as a final order on March 14, 2012, with respect to a workplace located at Annie Oakley 23-1, Rig 3 Pecos, TX 79772.