Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A & P SERVICES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A & P SERVICES INC. in REEVES 2723 LEASE, WELL #2, AQUILA RIG #3, 3 MILES N OF PECOS, PECOS, TX 79772 (NAICS 213112). OSHA activity number 339877896.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A & P Services INC. — free Get an email when a new federal OSHA severe-injury report for A & P Services INC. is published. One employer, no account, unsubscribe in one click.
Establishment
A & P SERVICES INC.
Site address
REEVES 2723 LEASE, WELL #2, AQUILA RIG #3, 3 MILES N OF PECOS
City
PECOS
State
TX
ZIP
79772
Mailing
PO BOX 79760, ODESSA, TX 79760
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
25
Ownership type
A

2 citations on file for this inspection.

1910.303 B02

Other-than-serious 1 instance 12 exposed
Issued
Oct 28, 2014
Abate by
Nov 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Drill site: On or about July 29, 2014, and at times prior thereto, employees working on Aquila Rig #3. Behind the trailers, there were two orange 25-foot 12 AWG extension cords connected together and were feeding two black 50-foot 12 AWG extension cords; the label states that this is prohibited. This condition can potentially expose employees to electrical hazards.
Recent events (1)
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 12 exposed
Issued
Oct 28, 2014
Abate by
Nov 3, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  Drill Site: On or about July 29, 2014, the strain relief to the water pump to the water and sewer system, located behind the crew living quarters was damaged. This condition exposed the employees to electrical hazards.
Recent events (1)
  • — Z (O) $0

View A & P Services INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339877896.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.