Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: FLORIDA CANCER SPECIALISTS, P.L.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of FLORIDA CANCER SPECIALISTS, P.L. in 2626 CARE DR., TALLAHASSEE, FL 32308 (NAICS 621111). OSHA activity number 339878134.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Florida Cancer Specialists, P.L. for free Get an email when a new federal OSHA severe-injury report for Florida Cancer Specialists, P.L. is published. One employer, no account, unsubscribe in one click.
Site address
2626 CARE DR.
City
TALLAHASSEE
State
FL
ZIP
32308
Mailing
2626 CARE DR., TALLAHASSEE, FL 32308
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
621111
Employees
24
Ownership type
A

9 citations on file for this inspection.

1910.157 E02

Serious Gravity 1 1 instance 20 exposed
Issued
Aug 28, 2014
Abate by
Sep 24, 2014
Penalty
Initial $2,550 · Current $1,530 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a. On or about July 30, 2014, at the employees' break-room, the fire extinguisher available for employees to use to put out small fires were not visually inspected at least monthly.  The last inspection was conducted in August of 2012.
Recent events (2)
  • · I (S) $1530
  • · Z (S) $2550

1910.157 E03

Serious Gravity 1 1 instance 20 exposed
Issued
Aug 28, 2014
Abate by
Sep 24, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a. On or about July 30, 2014, at the employees' break-room, the fire extinguisher available for employees to use to put out small fires was not subjected to an annual maintenance check.  The last inspection was conducted in August of 2012.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1030 D02 I

Serious Gravity 5 4 instances 14 exposed
Issued
Aug 28, 2014
Abate by
Oct 16, 2014
Penalty
Initial $5,100 · Current $3,060 Reduced
29 CFR 1910.1030(d)(2)(i): Engineering and work practice controls were not used to eliminate or minimize employees exposure:  a. On or about July 30, 2014, employees working as nurses and medical assistants were exposed to bloodborne pathogen hazards while assisting the physicians during bone marrow procedures, drawing blood, and providing oncology care to patients and the employer failed to use engineering controls or work practices that would eliminate or minimize exposures and identify particular engineering controls, such as self-sheathing needles or needleless systems among other controls.
Recent events (2)
  • · I (S) $3060
  • · Z (S) $5100

1910.1020 G01

Other-than-serious 3 instances 20 exposed
Issued
Aug 28, 2014
Abate by
Oct 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1020(g)(1): The employer did not inform current employees upon their first entering in to employment and at least annually thereafter, of the existence, location, and availability of any records covered by 29 CFR 1910:   a.  On or about July 30, 2014, the employer did not inform current employees of the existence, location, and availability of any records covered by 29 CFR 1910.1020 such as, but not limited to, safety data sheets and hepatitis b records, at least annually after hiring.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1030 C01 IV

Other-than-serious 4 instances 14 exposed
Issued
Aug 28, 2014
Abate by
Oct 16, 2014
Penalty
Initial $850 · Current $510 Reduced
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually:  a. On or about July 30, 2014, employees working as nurses and medical assistants were potentially exposed to bloodborne pathogens hazards while assisting the physician during bone morrow procedures, drawing blood, and while giving shots to the patients and the employer did not review their Exposure Control Plan (ECP) annually.  The employer provided a copy of an ECP with revision dates of April, 2009 and May, 2010.
Recent events (2)
  • · I (O) $510
  • · Z (O) $850

1910.1030 C01 IV A

Other-than-serious 1 instance 14 exposed
Issued
Aug 28, 2014
Abate by
Oct 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(iv)(A): The review and update of the exposure control plan did not reflect changes in technology that eliminate or reduce exposure to bloodborne pathogens:  a.  On or about July 30, 2014, employees working as nurses and medical assistants were potentially exposed to bloodborne pathogens while assisting the physicians during bone marrow procedures, drawing blood, and during patient's oncology care and the employer's written Exposure Control Plan  did not reflect innovations in procedure and technological developments changes in technology that eliminate or reduce exposure to bloodborne pathogens.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1030 C01 IV B

Other-than-serious 1 instance 14 exposed
Issued
Aug 28, 2014
Abate by
Oct 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(iv)(B): The review and update of the exposure control plan did not document annually consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure:  a.  On or about July 30, 2014, employees working as nurses and medical assistants were potentially exposed to bloodborne pathogens while assisting the physicians during bone marrow procedures, drawing blood, and during patient's oncology care and the employer did not document annual consideration and implementation of appropriate commercially available and effective medical devices designed to eliminate or minimize occupational exposure.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1030 C01 V

Other-than-serious 1 instance 14 exposed
Issued
Aug 28, 2014
Abate by
Oct 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(1)(v): The employer, who is required to establish an Exposure Control Plan, did not solicit input from non-managerial employees responsible for direct patient care who are potentially exposed to injuries from contaminated sharps in the identification, evaluation and selection of effective engineering and work practice controls:  a. On or about July 30, 2014, employees working as nurses and medical assistants were exposed to bloodborne pathogens hazards while assisting the physician during bone morrow procedures and during patient's oncology care and the employer did not solicit input from non-managerial employees in the identification, evaluation and selection of effective engineering and work practices.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1030 C02 I C

Other-than-serious 1 instance 14 exposed
Issued
Aug 28, 2014
Abate by
Oct 16, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(c)(2)(i)(C): The exposure determination did not include a list of all tasks and procedures or groups of closely related tasks and procedures in which occupational exposure occurs and that are performed by employees in job classifications listed in accordance with 29 CFR 1910.1030(c)(2)(i)(B):  a.  On or about July 30, 2014, the exposure determination contained in the employers' exposure control plan did not include a list of all tasks and procedures or groups of related tasks and procedures in which occupational exposure to bloodborne pathogens occurs such as, but not limited to, spill clean-up, operation of the centrifuge, assisting physicians during bone marrow procedures, and transporting biohazardous waste.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Florida Cancer Specialists, P.L.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339878134.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.