HONOLULU, HI —
OSHA Inspection: NEIMAN MARCUS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NEIMAN MARCUS in 1450 ALA MOANA BLVD 2101, HONOLULU, HI 96814 (NAICS 452111). OSHA activity number 339880486.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEIMAN MARCUS
- Site address
- 1450 ALA MOANA BLVD 2101
- City
- HONOLULU
- State
- HI
- ZIP
- 96814
- Mailing
- 1450 ALA MOANA BLVD 2101, HONOLULU, HI 96814
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 452111
- Employees
- 5000
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.305 B02 I
- Issued
- Sep 3, 2014
- Abate by
- Sep 9, 2014
- Penalty
- Initial $3,000 · Current $3,000
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: a. On August 1, 2014, in the receiving/loading dock, an energized four-plex outlet was missing faceplate exposing employees to an electrical shock hazards while plugging or unplugging cords.
Recent events (1)
- — Z (S) $3000
1910.22 D01
- Issued
- Sep 3, 2014
- Abate by
- Sep 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate: a) On August 1, 2014, in gift gallery stockroom, employees were exposed to the struck-by hazard of potentially overloading the overhead storage. b) On August 1, 2014, in men's sportswear stockroom employees were exposed to the struck-by hazard of potentially overloading the overhead storage. c) On August 1, 2014, in men's suits stockroom, employees were exposed to the struck-by hazard of potentially overloading the overhead storage. d) On August 1, 2014, in children's stockroom, employees were exposed to the struck-by hazard of potentially overloading the overhead storage. e) On August 1, 2014, in makeup stockroom, employees were exposed to the struck-by hazard of potentially overloading the overhead storage. f) On August 1, 2014, in Cusp stockroom, employees were exposed to the struck-by hazard of potentially overloading the overhead storage.
Recent events (1)
- — Z (O) $0
1910.36 G04
- Issued
- Sep 3, 2014
- Abate by
- Sep 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(g)(4): Objects that projected into the exit route reduced the width of the exit route to less than the 28 inches minimum width requirements for exit routes: a) On August 1, 2014; in the gift stockroom, material and products protruded into the passageway reduced the emergency egress to less than 28 inches. b) On August 1, 2014; in the gift stockroom, material and products protruded into the passageway reduced the emergency egress to less than 28 inches. c) On August 1, 2014; in the children's stockroom, material and products protruded into the passageway reduced the emergency egress to less than 28 inches.
Recent events (1)
- — Z (O) $0
1910.158 C02 I
- Issued
- Sep 3, 2014
- Abate by
- Sep 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.158(c)(2)(i): The employer did not assure that hose outlets and connections were accessible to employees: a. On August 1, 2014, in the load/receiving dock area, employees were exposed to a trip and fire hazard from material stored in front of the fire suppression system.
Recent events (1)
- — Z (O) $0
1910.303 G01 II
- Issued
- Sep 3, 2014
- Abate by
- Sep 13, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) On August 1, 2014, in the electrical closet on the third floor, material was stored in front of the electrical panel exposed employees to electrical hazards. b) On August 1, 2014, in the kitchen on the third floor, material was stored in front of the electrical panel exposed employees to electrical hazards. c) On August 1, 2014, in the receiving/ loading dock, material was stored in front of the electrical panel exposed employees to electrical hazards.
Recent events (1)
- — Z (O) $0
More inspections at Neiman Marcus
View Neiman Marcus's full OSHA safety record →
More inspections in this industry (NAICS 452111)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339880486.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.