CHESTER, NY ·
OSHA Inspection: F.A. ALPINE WINDOW MANUFACTURING CORP.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of F.A. ALPINE WINDOW MANUFACTURING CORP. in 1683 ROUTE 17M, CHESTER, NY 10918 (NAICS 332321). OSHA activity number 339881385.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- F.A. ALPINE WINDOW MANUFACTURING CORP.
- Site address
- 1683 ROUTE 17M
- City
- CHESTER
- State
- NY
- ZIP
- 10918
- Mailing
- 1683 ROUTE 17M, CHESTER, NY 10918
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 5
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.23 C01
- Issued
- Sep 25, 2014
- Abate by
- Oct 1, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) Welding Area Dock Door - On or about August 4, 2014, the welding area dock door did not have a standard rail exposing employees to fall hazards.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.178 L01 I
- Issued
- Sep 25, 2014
- Abate by
- Oct 7, 2014
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Shop - On or prior to August 4, 2014, employees operate a forklift in the facility without training and evaluation of operating performance.
Recent events (2)
- · I (O) $0
- · Z (S) $1200
1910.253 B04 III
- Issued
- Sep 25, 2014
- Abate by
- Oct 1, 2014
- Penalty
- Initial $2,400 · Current $2,200 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) Shop Floor - On or about August 4, 2014, an oxygen cylinder was stored next to incompatible materials including an Acetylene cylinder (flammable gas) and Liquefied Petroleum Gas UN 1075 (flammable gas).
Recent events (2)
- · I (S) $2200
- · Z (S) $2400
1910.303 B02
- Issued
- Sep 25, 2014
- Abate by
- Nov 13, 2014
- Penalty
- Initial $1,200 · Current $596 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Welding Area - On or about August 4, 2014, a single receptacle electrical outlet box meant for mounting on the wall was used for pendant application power access.
Recent events (2)
- · I (S) $596
- · Z (S) $1200
1910.303 F02
- Issued
- Sep 25, 2014
- Abate by
- Oct 1, 2014
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Office Area - On or about August 4, 2014, a 220 Volt electrical service panel box breaker switches were not labeled. b) Shop Area - On or about August 4, 2014, a 200 Volt 3-Phase electrical service panel box breaker switches were not labeled. c) Shop Area - On or about August 4, 2014, a 200 Volt 3-Phase electrical service panel box breaker switches were not labeled. d) Welding Area - On or about August 4, 2014, a 200 Volt 3-Phase electrical service panel box breaker switches were not labeled.
Recent events (2)
- · I (S) $0
- · Z (S) $1200
1910.303 G02 I
- Issued
- Sep 25, 2014
- Abate by
- Oct 1, 2014
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) Shop Area - On or about August 4, 2014, an electrical service panel box did not have a panel door or cover, exposing live electrical components. b) Shop Area - On or about August 4, 2014, an electrical service panel box did not have a panel door or cover, exposing live electrical components. c) Welding Area - On or about August 4, 2014, an electrical service panel box did not have a panel door or cover, exposing live electrical components.
Recent events (2)
- · I (S) $0
- · Z (S) $1600
More inspections at F.A. Alpine Window Manufacturing Corp.
View F.A. Alpine Window Manufacturing Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339881385.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.