Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARAVEO, ROBERT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARAVEO, ROBERT in 551 HOYT LANE, LOUISVILLE, CO 80027 (NAICS 238170). OSHA activity number 339882466.

Watch Caraveo, Robert — free Get an email when a new federal OSHA severe-injury report for Caraveo, Robert is published. One employer, no account, unsubscribe in one click.
Establishment
CARAVEO, ROBERT
Site address
551 HOYT LANE
City
LOUISVILLE
State
CO
ZIP
80027
Mailing
810 OSWEGO STREET, AURORA, CO 80010
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $800.00 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    (a)Caraveo, Robert dba RC Construction at 551 Hoyt Lane, Louisville, CO 80027:  On and before August 2nd, 2014, the exposing employer did not ensure that employees wore safety glasses when using or working in the vicinity of pneumatic nail guns.  The condition exposed employees to the hazard of projectiles to the eyes.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a)Caraveo, Robert dba RC Construction at 551 Hoyt Lane, Louisville, CO 80027:  On and before August 2nd, 2014, the exposing employer did not ensure that employees were protected from falling because of the following deficiencies with the guardrail system:        1)  The top rail did not extend across the full length of the platform;        2)  The guardrail system was missing its midrail;        3)  The guardrail system was missing its end rails;        4)  The guardrails did not support a 200 pound side load because the uprights were more than 8 feet apart, and were used to support a 2 x 4 top rail; and        5)  The guardrails did not support a 200 pound side load because the horizontal prongs supporting the uprights fit into the pump jack scaffold platform, but these prongs were not pinned on the backside to prevent the prongs and uprights from being pushed out.    The conditions exposed employees to a 13 foot fall hazard.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339882466.