GREENWOOD VILLAGE, CO —
OSHA Inspection: JD MASONRY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JD MASONRY LLC in 4101 PRESERVE PARKWAY NORTH, GREENWOOD VILLAGE, CO 80121 (NAICS 238140). OSHA activity number 339885303.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JD MASONRY LLC
- Site address
- 4101 PRESERVE PARKWAY NORTH
- City
- GREENWOOD VILLAGE
- State
- CO
- ZIP
- 80121
- Mailing
- PO BOX 3850, AVON, CO 81620
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,600 · Current $1,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by, crushing and falling hazards: (a) On or about August 6, 2014, the operator of the Sky Trak 6036 rough terrain fork truck did not wear the vehicle's seatbelt while operating it at the construction site. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $1000
- — Z (S) $1600
1926.300 B04 II
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded: (a) On or about August 6, 2014, and at times prior, the employer did not protect employees from the point of operation on the Workman II 350 portable concrete mixer located on the south side of the house under construction. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $1000
- — Z (S) $2000
1926.300 B02
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded: (a) On or about August 6, 2014, and at times prior employees were exposed to caught-in hazards from the unguarded belt and pulley and drive shaft next to the off switch of the Workman II 350 portable concrete mixer. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.451 B01
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,600 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) On or about August 6, 2014, and at times prior, the employer did not protect employees from falls while working on a scaffold that was not fully planked between the uprights and the guardrail supports. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $1500
- — Z (S) $1600
1926.451 F03
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) On or about August 6, 2014, and at times prior, the employer did not ensure the scaffold was inspected and free of visible defects before allowing workers to work from the scaffold. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.451 F14
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: (a) On or about August 6, 2014, and at times prior, the employees were exposed to falls from a scaffold that had cinder blocks on a platform supporting planking of another platform from which the employees were working. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.451 G01
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $0 · Current $1,000
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: (a) On or about August 6, 2014, and at times prior, the employer did not protect employees from falls when working from the top level of a scaffold that was greater than 21 feet above the ground and did not have guardrails or other methods of fall protection. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $1000
- — Z (S) $0
1926.451 E01
- Issued
- Oct 13, 2014
- Abate by
- Oct 21, 2014
- Penalty
- Initial $1,600 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: (a) On or about August 6, 2014, and at times prior, the employer did not protect employees from falls when they climbed crossbraces to descend from the scaffold. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (O) $1500
- — Z (S) $1600
More inspections at JD Masonry LLC
View JD Masonry LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339885303.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.