RIVERTON, IL ·
OSHA Inspection: S.I.C. RECYCLING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of S.I.C. RECYCLING, INC. in 2200 OVERPASS ROAD, RIVERTON, IL 62561 (NAICS 423930). OSHA activity number 339888760.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S.I.C. RECYCLING, INC.
- Site address
- 2200 OVERPASS ROAD
- City
- RIVERTON
- State
- IL
- ZIP
- 62561
- Mailing
- 2200 OVERPASS ROAD, RIVERTON, IL 62561
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 29
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.134 C02 I
- Issued
- Dec 10, 2014
- Abate by
- Dec 22, 2014
- Penalty
- Initial $3,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to this section when the employer determined that any voluntary respirator use was permissible: Employees were allowed to wear dust masks while working in the facility and the employer did not provide the employees with the information contained in Appendix D of respirator standard.
Recent events (2)
- · I (S) $1500
- · Z (S) $3000
1910.134 D01 III
- Issued
- Dec 10, 2014
- Abate by
- Feb 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form: The employer allowed employees exposed to aluminum dust and other particulates to wear dust masks and the employer did not determine levels of exposure.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 G01 I A
- Issued
- Dec 10, 2014
- Abate by
- Dec 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting face pieces were worn by employees who had facial hair that came between the sealing surface of the face piece and the face: The employer did not prohibit employees who had facial hair that came between the sealing surface of the face piece and the face from wearing a negative pressure respirator (N95).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C04 II
- Issued
- Dec 10, 2014
- Abate by
- Dec 22, 2014
- Penalty
- Initial $4,000 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section: Employees were exposed to hazardous energy when placing a brush inside an opening that had been cut on the side of the Endura-Veyor Conveyor and there were no specific procedural steps for isolating the hazardous energy.
Recent events (2)
- · I (S) $2000
- · Z (S) $4000
1910.147 D03
- Issued
- Dec 10, 2014
- Abate by
- Dec 22, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: Employees performing servicing and maintenance operations were exposed to getting their hands/fingers caught in the moving part of the conveyor and a suitable energy isolating device was not used.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 423930)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339888760.