Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: S.I.C. RECYCLING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of S.I.C. RECYCLING, INC. in 2200 OVERPASS ROAD, RIVERTON, IL 62561 (NAICS 423930). OSHA activity number 339888760.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S.I.C. Recycling, INC. for free Get an email when a new federal OSHA severe-injury report for S.I.C. Recycling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2200 OVERPASS ROAD
City
RIVERTON
State
IL
ZIP
62561
Mailing
2200 OVERPASS ROAD, RIVERTON, IL 62561
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
29
Ownership type
Private (A)

5 citations on file for this inspection.

1910.134 C02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 10, 2014
Abate by
Dec 22, 2014
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to this section when the employer determined that any voluntary respirator use was permissible:      Employees were allowed to wear dust masks while working in the facility and the employer did not provide the employees with the information contained in Appendix D of respirator standard.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3000

1910.134 D01 III

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 10, 2014
Abate by
Feb 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; this evaluation shall include a reasonable estimate of employee exposures to respiratory hazard(s) and an identification of the contaminant's chemical state and physical form:     The employer allowed employees exposed to aluminum dust and other particulates to wear dust masks and the employer did not determine levels of exposure.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 G01 I A

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 10, 2014
Abate by
Dec 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting face pieces were worn by employees who had facial hair that came between the sealing surface of the face piece and the face:  The employer did not prohibit employees who had facial hair that came between the sealing surface of the face piece and the face from wearing a negative pressure respirator (N95).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 10, 2014
Abate by
Dec 22, 2014
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy, including, but not limited to Items A-D of this section:       Employees were exposed to hazardous energy when placing a brush inside an opening that had been cut on the side of the Endura-Veyor Conveyor and there were no specific procedural steps for isolating the hazardous energy.
Recent events (2)
  • · I (S) $2000
  • · Z (S) $4000

1910.147 D03

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 10, 2014
Abate by
Dec 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:     Employees performing servicing and maintenance operations were exposed to getting their hands/fingers caught in the moving part of the conveyor and a suitable energy isolating device was not used.