Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: GERRALD'S MECHANICAL SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GERRALD'S MECHANICAL SERVICES, INC. in LOT 134, POOLER, GA 31322 (NAICS 238220). OSHA activity number 339889727.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gerrald'S Mechanical Services, INC. for free Get an email when a new federal OSHA severe-injury report for Gerrald'S Mechanical Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
LOT 134
City
POOLER
State
GA
ZIP
31322
Mailing
P.O. BOX 459, RICHMOND HILL, GA 31324
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
3
Ownership type
Private (A)

2 citations on file for this inspection.

1926.1052 C01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 15, 2014
Abate by
Aug 27, 2014
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  a) Inside, 1st level stairwell, on or about August 6, 2014, the employer did not ensure handrails were installed prior to use, exposing employees to about a 10-foot fall hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1926.1052 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 15, 2014
Abate by
Aug 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a) Inside, 1st level stairwell, on or about August 6, 2014, the employer did not ensure a stairrail was installed on the unprotected side prior to use, exposing employees to about a 4-foot fall hazard.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339889727.