Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DAKKOTA INTEGRATED SYSTEMS, L.L.C.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DAKKOTA INTEGRATED SYSTEMS, L.L.C. in 12519 SOUTH BURLEY AVENUE, CHICAGO, IL 60633 (NAICS 336399). OSHA activity number 339892275.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dakkota Integrated Systems, L.L.C. — free Get an email when a new federal OSHA severe-injury report for Dakkota Integrated Systems, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
12519 SOUTH BURLEY AVENUE
City
CHICAGO
State
IL
ZIP
60633
Mailing
12519 SOUTH BURLEY AVENUE, CHICAGO, IL 60633
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
296
Ownership type
A

2 citations on file for this inspection.

1910.178 O02

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 17, 2014
Abate by
Nov 4, 2014
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.178(o)(2): Only loads within the rated capacity of the truck shall be handled.   a.  On or about August 7, 2014, in the fascia 502-DLOC area, a forklift operator was required to lift loads exceeding the forklift's rated capacity of 4400 pounds. The forklift was carrying a load of 4482 pounds. Employees were exposed to the hazards associated with forklift tipping and turnover.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.303 G01 VII

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2014
Abate by
Oct 1, 2014
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.303(g)(1)(vii): Switchboards, panelboards, and distribution boards installed for the control of light and power circuits, and motor control centers shall be located in dedicated spaces and protected from damage.   On or about August 7, 2014, in the rear fascia side by station 11, line 385, employees were required to use a forklift to move materials to and from a rack passing directly in front of an electrical control panel.  Employees were thereby exposed to the hazards associated with electrical shock.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5000

View Dakkota Integrated Systems, L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339892275.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.