Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: REYNOLDS NATIONWIDE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of REYNOLDS NATIONWIDE in 121 US HIGHWAY 42 NE, LONDON, OH 43140 (NAICS 484220). OSHA activity number 339893125.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reynolds Nationwide — free Get an email when a new federal OSHA severe-injury report for Reynolds Nationwide is published. One employer, no account, unsubscribe in one click.
Establishment
REYNOLDS NATIONWIDE
Site address
121 US HIGHWAY 42 NE
City
LONDON
State
OH
ZIP
43140
Mailing
121 US HIGHWAY 42 NE, LONDON, OH 43140
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484220
Employees
10
Ownership type
A

12 citations on file for this inspection.

1910.146 C04

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146:    a. At the workplace in the Wash Bay area, employees were assigned to perform cleaning operations inside food transportation tankers (permit-required confined spaces).      The employer's written permit-required confined space entry program did not provide specific information to ensure compliance with all of the applicable elements under 1910.146(d) such as, but not limited to:           a.  Procedures to prevent unauthorized entry.   b.  Procedures to identify and evaluate the hazards of permit spaces.       c.  Procedures necessary for safe permit space entry operations (acceptable conditions for entry, providing entrants or their representatives with the opportunity to observe monitoring or testing of permit spaces, ventilating the permit space as necessary to eliminate or control atmospheric hazards, protection from external hazards, and verifying that conditions are acceptable for entry throughout the duration of entry).   d.  Procedures for providing testing and monitoring equipment, ventilating equipment, and rescue and emergency equipment.     e.  Procedures for evaluating permit space conditions when entry operations are conducted (testing and monitoring).       f.  Procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and for preventing unauthorized personnel from attempting a rescue.     g.  Procedures for preparing, issuing, using, and canceling entry permits.   h.  Procedures for reviewing and revising entry operations.   i.  Procedures for reviewing and revising the permit space program.
Recent events (3)
  • — F (S) $5000
  • — C (S) $7000
  • — Z (S) $7000

1910.146 D03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $7,000 · Current $5,000 Reduced
The employer shall develop and implement the means, procedures, and practices necessary for safe permit space entry operations including:    29 CFR 1910.146(d)(3)(i): Specifying acceptable entry conditions;      a. At the workplace in the Wash Bay area, the employer did not specify the acceptable and safe entry conditions for employees assigned to perform cleaning operations in the food transport tankers (permit-required confined spaces).
Recent events (3)
  • — F (S) $5000
  • — C (S) $7000
  • — Z (S) $7000

1910.146 D03 VI

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(3)(vi): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to:  verifying the conditions in the permit space were acceptable throughout the duration of an authorized entry:            a. At the workplace in the Wash Bay area, the employer did not verify that entry conditions inside of food transport tankers were safe and acceptable for entry and throughout the duration of entry (permit-required confined spaces).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 D06

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(6): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations:    a. At the workplace in the Wash Bay area, an attendant was not provided outside the food transport tankers while an employee was inside the tankers performing cleaning operations (permit-required confined spaces).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 D09

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.146(d)(9): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces.     a. At the workplace in the Wash Bay area, the employer did not develop and implement procedures for summoning rescue and emergency services for employees performing cleaning operations inside food transport tankers (permit-required confined spaces).
Recent events (3)
  • — F (S) $5000
  • — C (S) $7000
  • — Z (S) $7000

1910.146 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.146(e)(1): Before entry is authorized, the employer shall document the completion of measures required by paragraph (d)(3) of this section by preparing an entry permit.     a. At the workplace in the Wash Bay area, the employer did not complete entry permits for employees performing cleaning operations inside of food transport tankers (permit-required confined spaces).
Recent events (3)
  • — F (S) $5000
  • — C (S) $7000
  • — Z (S) $7000

1910.146 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $7,000 · Current $5,000 Reduced
29 CFR 1910.146(g)(1): The employer shall provide training so that all employees whose work is regulated by this section acquire the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this section.    a. At the workplace in the Wash Bay area, employees performing cleaning operations inside food transportation tankers were exposed to impalement, slipping, and atmospheric hazards.  The employer did not provide adequate permit required confined space training to entrants, attendants, and supervisors.
Recent events (3)
  • — F (S) $5000
  • — C (S) $7000
  • — Z (S) $7000

1910.305 A02 X

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $4,000 · Current $5,000
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.    a. At the workplace in the Wash Bay area, employees were exposed to a flexible cord that had energized, exposed copper wiring. The flexible cord was not protected against the sharp edges of the sheet metal wall it had been run through.
Recent events (3)
  • — F (S) $5000
  • — C (S) $4000
  • — Z (S) $4000

1910.305 G01 IV B

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $0 · Current $0
Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:    29 CFR 1910.305(g)(1)(iv)(B): Where run through holes in walls, ceilings, or floors;      a. At the workplace in the Wash Bay area, employees were exposed to a flexible cord that had been run through a through a hole in a sheet metal wall.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.132 A

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $70,000 · Current $5,000 Reduced
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.    a. At the workplace in the Wash Bay area, employees were exposed to fall hazards of approximately 10'9" while performing cleaning operations on top of food transport tankers and were not provided with fall protection.
Recent events (3)
  • — F (S) $5000
  • — C (W) $70000
  • — Z (W) $70000

1910.146 D03 IV

Deleted Willful Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Feb 11, 2015
Penalty
Initial $70,000 · Current $0 Reduced
29 CFR 1910.146(d)(3)(iv): Under the permit space program, the employer did not develop and implement the means, procedures, and practices necessary for safe permit entry operations, including, but not limited to, purging, inerting,  flushing or ventilating the permit spaces as necessary to eliminate or control atmospheric hazards.  a. At the workplace in the Wash Bay area, employees were exposed to atmospheric hazards while performing cleaning operations inside food transportation tankers.  The employer did not ensure forced air ventilation was used before and during employee entry into the permit-required confined spaces.
Recent events (3)
  • — F (W) $0
  • — C (W) $70000
  • — Z (W) $70000

1910.146 D05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2015
Abate by
Oct 6, 2016
Penalty
Initial $0 · Current $5,000
Permit-required confined space program (permit space program). Under the permit space program required by paragraph (c)(4) of this section, the employer shall:    29 CFR 1910.146(d)(5)(i): Test conditions in the permit space to determine if acceptable entry conditions exist before entry is authorized to begin, except that, if isolation of the space is infeasible because the space is large or is part of a continuous system (such as a sewer), pre-entry testing shall be performed to the extent feasible before entry is authorized and, if entry is authorized, entry conditions shall be continuously monitored in the areas where authorized entrants are working;      a. At the workplace in the Wash Bay area, employees were exposed to atmospheric hazards while performing cleaning operations inside food transportation tankers.  The employer did not ensure atmospheric testing was performed prior to employees entering the permit-required confined space.
Recent events (3)
  • — F (S) $5000
  • — C (W) $0
  • — Z (W) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339893125.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.