Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: GRAYDEN CEDARWORKS

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of GRAYDEN CEDARWORKS in 8782 RANCH RD 2169, JUNCTION, TX 76849 (NAICS 321114). OSHA activity number 339893612.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Grayden Cedarworks for free Get an email when a new federal OSHA severe-injury report for Grayden Cedarworks is published. One employer, no account, unsubscribe in one click.
Establishment
GRAYDEN CEDARWORKS
Site address
8782 RANCH RD 2169
City
JUNCTION
State
TX
ZIP
76849
Mailing
8782 RANCH RD 2169, JUNCTION, TX 76849
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321114
Employees
18
Ownership type
A

4 citations on file for this inspection.

1910.68 B08 I

Serious Gravity 5 6 instances 4 exposed
Issued
Feb 6, 2015
Abate by
Feb 16, 2015
Penalty
Initial $3,500 · Current $2,800 Reduced
29 CFR 1910.68(b)(8)(i): Guard rail requirement. The entrances and exits at all floor landings affording access to the manlift were not guarded by a maze (staggered railing) or a handrail equipped with self-closing gates:    At the Humphrey Manlift Elevator, On or about August 08,2014 and at times prior to, employees were exposed to a fall hazard of approximately 20 in height to the ground level below while walking and working around the Humphrey Manlift Elevator, Serial #: S-3467, Model #: 14S GHC-3-PA, that was not equipped with self-closing gates.
Recent events (2)
  • · I (S) $2800
  • · Z (S) $3500

1910.68 C07 I

Other-than-serious 4 instances 4 exposed
Issued
Feb 6, 2015
Abate by
Feb 16, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.68(c)(7)(i): Instruction signs at landings or belts. Signs of conspicuous and easily read style giving instructions for the use of the manlift were not posted at each landing or stenciled on the belt:    a) At the Humphrey Manlift Elevator, On or about August 08,2014 and at times prior to, employees were exposed to a fall hazard of approximately 20 feet in height from a Humphrey Manlift Elevator, Serial #: S-3467, Model #: 14S GHC-3-PA while operating a manlift without posted instructions on the proper use; such as but not limited to signs stating: "Face the Belt", "Use the Handhold", "To Stop, Pull Rope in Direction of Travel".
Recent events (2)
  • · I (O) $2100
  • · Z (S) $3500

1910.68 C07 II A

Other-than-serious 1 instance 4 exposed
Issued
Feb 6, 2015
Abate by
Feb 16, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.68(c)(7)(ii)(a): At the top floor an illuminated sign were not displayed bearing the following wording:   "TOP FLOOR - GET OFF"    At the Humphrey Manlift Elevator, On or about August 08,2014 and at times prior to, employees were exposed to a fall of approximately 20 feet in height while riding the Humphrey Manlift Elevator, Serial #: S-3467, Model #: 14S GHC-3-PA, which  did not have an illuminated sign to indicate the following wording:  TOP FLOOR- GET OFF.
Recent events (2)
  • · I (O) $2100
  • · Z (S) $3500

1910.68 E01

Serious Gravity 10 3 instances 4 exposed
Issued
Feb 6, 2015
Abate by
Feb 16, 2015
Penalty
Initial $4,900 · Current $3,920 Reduced
29 CFR 1910.68(e)(1): All manlifts were not inspected by a competent designated person at intervals of not more than 30 days:         At the Humphrey Manlift Elevator, On or about August 08, 2014 and at times prior to, employees were exposed to a struck-by hazard from descending steps while riding/operating the Humphrey Manlift Elevator, Serial #: S-3467, Model #: 14S GHC-3-PA, which had not been periodically inspected, and automatic safety stops were not functioning to shut off the electric power and apply the brake when a loaded step passes the bottom landing.
Recent events (2)
  • · I (S) $3920
  • · Z (S) $4900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339893612.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.