VANCOUVER, WA ·
OSHA Inspection: NATIONAL PARK SERVICE FT. VANCOUVER
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NATIONAL PARK SERVICE FT. VANCOUVER in 400 E 5TH ST., VANCOUVER, WA 98668 (NAICS 712190). OSHA activity number 339894156.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL PARK SERVICE FT. VANCOUVER
- Site address
- 400 E 5TH ST.
- City
- VANCOUVER
- State
- WA
- ZIP
- 98668
- Mailing
- 612 RESERVE ST., VANCOUVER, WA 98661
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712190
- Employees
- 30
- Ownership type
- Federal government (D)
Citations
4 citations on file for this inspection.
1910.215 A04
- Issued
- Sep 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: A) In the maintenance shop, there was a bench grinder had its work rest 1/4 inch from the surface of the grinding wheel.
Recent events (1)
- · Z (S) $0
1910.215 B09
- Issued
- Sep 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: A) The bench grinder in the building 400 maintenance shop had it's tongue guard adjusted 1/2 inch from the surface of the wheel.
Recent events (1)
- · Z (S) $0
1910.303 B01
- Issued
- Sep 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1): A) In the Building 400 maintenance shop break area, a toaster, microwave oven, toaster oven, and refrigerator were all plugged into a 15 amp power strip, which was plugged into a 15 amp wall outlet.
Recent events (1)
- · Z (S) $0
1910.157 C01
- Issued
- Sep 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: A) In the maintenance shop, one of the fire extinguishers was placed on the floor instead of being mounted to the wall.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 712190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339894156.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.