CAZENOVIA, NY ·
OSHA Inspection: DELIA HEATING VENTILATION & AIR CONDITIONING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DELIA HEATING VENTILATION & AIR CONDITIONING, INC. in ECKEL HALL, CAZENOVIA COLLEGE, 22 SULLIVAN STREET, CAZENOVIA, NY 13035 (NAICS 238220). OSHA activity number 339894602.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELIA HEATING VENTILATION & AIR CONDITIONING, INC.
- Site address
- ECKEL HALL, CAZENOVIA COLLEGE, 22 SULLIVAN STREET
- City
- CAZENOVIA
- State
- NY
- ZIP
- 13035
- Mailing
- 701 WEST BELDEN AVENUE, SYRACUSE, NY 13204
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.1053 B01
- Issued
- Aug 27, 2014
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Third floor, Equipment Laboratory, roof hatch, on or about 8-7-14: Two employees were accessing a mezzanine area via an extension ladder section that was even with the landing surface, exposing the employees to a fall hazard of 11 feet 10 inches.
Recent events (2)
- · I (S) $960
- · Z (S) $1600
1926.1053 B04
- Issued
- Aug 27, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Third floor, Equipment Laboratory, roof hatch, on or about 8-7-14: Two employees were accessing a mezzanine area via a section of extension ladder section that was not being used as designed or for its intended purpose, exposing the employees to a fall hazard of 11 feet 10 inches.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Delia Heating Ventilation & AIR Conditioning, INC.
View Delia Heating Ventilation & AIR Conditioning, INC.'s full OSHA safety record →