Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: COOKTEK INDUCTION SYSTEMS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COOKTEK INDUCTION SYSTEMS, LLC in 870 WEST DIVISION STREET UNIT A, CHICAGO, IL 60601 (NAICS 333994). OSHA activity number 339896995.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cooktek Induction Systems, LLC for free Get an email when a new federal OSHA severe-injury report for Cooktek Induction Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
870 WEST DIVISION STREET UNIT A
City
CHICAGO
State
IL
ZIP
60601
Mailing
870 W. DIVISION ST., CHICAGO, IL 60601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333994
Employees
35
Ownership type
Private (A)

2 citations on file for this inspection.

1910.22 B01

Serious Gravity 1 2 instances 2 exposed
Issued
Sep 19, 2014
Penalty
Initial $1,785 · Current $1,250 Reduced
29 CFR 1910.22(b)(1): Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repairs, with no obstruction across or in aisles that could create a hazard.  Warehouse - On or about August 13, 2014, in the warehouse, employees were required to operate powered industrial vehicles. The aisle ways in the southwest corner of the warehouse were not kept clear (blocked by overstock). Employees were thereby exposed to the hazards associated with blocked aisles and passageways.
Recent events (2)
  • · I (S) $1249.5
  • · Z (S) $1785

1910.157 C04

Other-than-serious 2 instances 33 exposed
Issued
Sep 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): The employer shall assure that portable fire extinguishers are maintained in a fully charged and operable condition and kept in their designated places at all times except during use.  Warehouse - On or about August 13, 2014, the employer did not ensure that all portable fire extinguishers were kept in their designated places at all times. One (1) fire extinguishers in the west corridor exit of the warehouse was not present at the designated location.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339896995.