CHICAGO, IL ·
OSHA Inspection: VELEZ IRON WORKS INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VELEZ IRON WORKS INC in 2760 N. MILWAUKEE AVE., CHICAGO, IL 60647 (NAICS 238190). OSHA activity number 339897522.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VELEZ IRON WORKS INC
- Site address
- 2760 N. MILWAUKEE AVE.
- City
- CHICAGO
- State
- IL
- ZIP
- 60647
- Mailing
- 2103 N. MAJOR AVE., CHICAGO, IL 60639
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 4
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1903.19 C01
- Issued
- Apr 14, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Velez Iron Works, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 01a 02/18/2015 01 01b 02/18/2015 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- · Z (O) $400
1926.350 A09
- Issued
- Feb 11, 2015
- Abate by
- Feb 18, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times: a) On or about August 12, 2014, oxygen and acetylene cylinders were stored in an upright position but were not secured. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- · Z (S) $2000
1926.350 A10
- Issued
- Feb 11, 2015
- Abate by
- Feb 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) On or about August 12, 2014, the employer did not ensure that while in storage, oxygen cylinder was separated from the acetylene cylinder by a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- · Z (S) $0
1926.403 I02 I
- Issued
- Feb 11, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) On or about August 12, 2014, employees were exposed to electrical hazards where electrical panels did not have covers exposing them to accidental contact with live parts. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $2800
1926.405 B02
- Issued
- Feb 11, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about August 12, 2014, employees were exposed to electrical hazards while using electrical equipment plugged into an outlet receptacle which was not attached to the outlet box and did not have a faceplate. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $0
1926.405 J01 I
- Issued
- Feb 11, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts exposed to employee contact: a) On or about August 12, 2014, employees were exposed to electrical hazards while using electrical equipment plugged into an outlet receptacle which was not attached to the outlet box and did not have a faceplate, which exposed live parts. No abatement certification or documentation is required for this item.
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238190)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339897522.