OSHA Inspection: VELEZ IRON WORKS INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VELEZ IRON WORKS INC in 2760 N. MILWAUKEE AVE., CHICAGO, IL 60647 (NAICS 238190). OSHA activity number 339897522.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Velez Iron Works INC for free Get an email when a new federal OSHA severe-injury report for Velez Iron Works INC is published. One employer, no account, unsubscribe in one click.
Site address
2760 N. MILWAUKEE AVE.
City
CHICAGO
State
IL
ZIP
60647
Mailing
2103 N. MAJOR AVE., CHICAGO, IL 60639
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
4
Ownership type
Private (A)

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Apr 14, 2015
Abate by
May 15, 2015
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1):  The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:     Velez Iron Works, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:     Citation Number                       Item Number                            Abatement Date  01                                                  01a                                         02/18/2015  01                                                  01b                                         02/18/2015       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (O) $400

1926.350 A09

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2015
Abate by
Feb 18, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.350(a)(9):  Compressed gas cylinders were not secured in an upright position at all times:    a)  On or about August 12, 2014, oxygen and acetylene cylinders were stored in an upright position but were not secured.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (S) $2000

1926.350 A10

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 11, 2015
Abate by
Feb 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.350(a)(10):  Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a)  On or about August 12, 2014, the employer did not ensure that while in storage, oxygen cylinder was separated from the acetylene cylinder by a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • · Z (S) $0

1926.403 I02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 11, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:    a)  On or about August 12, 2014, employees were exposed to electrical hazards where electrical panels did not have covers exposing them to accidental contact with live parts.     No abatement certification or documentation is required for this item.
Recent events (1)
  • · Z (S) $2800

1926.405 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  a)  On or about August 12, 2014, employees were exposed to electrical hazards while using electrical equipment plugged into an outlet receptacle which was not attached to the outlet box and did not have a faceplate.   No abatement certification or documentation is required for this item.
Recent events (1)
  • · Z (S) $0

1926.405 J01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(j)(1)(i):  Fixtures, lampholders, lamps, rosettes, or receptacles had live parts exposed to employee contact:  a)  On or about August 12, 2014, employees were exposed to electrical hazards while using electrical equipment plugged into an outlet receptacle which was not attached to the outlet box and did not have a faceplate, which exposed live parts.     No abatement certification or documentation is required for this item.