Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CLEAR HORIZONS DANE, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CLEAR HORIZONS DANE, LLC in 6321 CUBA VALLEY RD, DANE, WI 53529 (NAICS 221117). OSHA activity number 339897688.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clear Horizons Dane, LLC for free Get an email when a new federal OSHA severe-injury report for Clear Horizons Dane, LLC is published. One employer, no account, unsubscribe in one click.
Site address
6321 CUBA VALLEY RD
City
DANE
State
WI
ZIP
53529
Mailing
6321 CUBA VALLEY RD, DANE, WI 53529
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221117
Employees
9
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Feb 3, 2015
Abate by
Feb 25, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about August 6, 2014, the employer did not have a written procedure for isolation of hazardous energy of the methane pipe for Digester 1.    Abatement documentation required per 29 CFR 1903.19(d).
Recent events (3)
  • · F (O) $2000
  • · C (S) $2000
  • · Z (S) $2000

1910.147 D06

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 3, 2015
Abate by
Feb 25, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:    On or about August 6, 2014, an authorized employee did not verify that the methane pipe had been isolated prior to cleanout of Digester 1.    Abatement documentation required per 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $0
  • · C (S) $2000
  • · Z (S) $2000

1910.307 C

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 3, 2015
Abate by
Feb 25, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  On or about August 6, 2014, an employee was using a leaf blower that was not intrinsically safe in a hazardous atmosphere.  Abatement documentation required per 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $2000
  • · C (S) $2000
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339897688.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.