Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VOLVO PARTS NORTH AMERICA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VOLVO PARTS NORTH AMERICA, INC. in 8355 HIGHFIELD DRIVE NORTH, LEWIS CENTER, OH 43035 (NAICS 441110). OSHA activity number 339898777.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Volvo Parts North America, INC. — free Get an email when a new federal OSHA severe-injury report for Volvo Parts North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8355 HIGHFIELD DRIVE NORTH
City
LEWIS CENTER
State
OH
ZIP
43035
Mailing
8355 HIGHFIELD DRIVE NORTH, LEWIS CENTER, OH 43035
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
235
Ownership type
A

5 citations on file for this inspection.

1910.37 A03

Other-than-serious 1 instance 50 exposed
Issued
Sep 4, 2014
Abate by
Feb 11, 2016
Penalty
Initial $3,000 · Current $1,500 Reduced
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.    a. In the Green Meadows Building near man door 01, the emergency exit was obstructed.
Recent events (3)
  • — F (O) $1500
  • — C (S) $3000
  • — Z (S) $3000

1910.151 C

Other-than-serious 1 instance 150 exposed
Issued
Sep 4, 2014
Abate by
Feb 11, 2016
Penalty
Initial $3,000 · Current $2,000 Reduced
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.    a. In the bomb room, the emergency eye wash station was blocked by stored parts and was not available for immediate use.
Recent events (3)
  • — F (O) $2000
  • — C (S) $3000
  • — Z (S) $3000

1910.157 C01

Deleted Serious Gravity 1 1 instance 150 exposed
Issued
Sep 4, 2014
Abate by
Sep 16, 2014
Penalty
Initial $3,000 · Current $0 Reduced
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  a. In aisle 48, a pallet of parts was stored in front of a portable fire extinguisher, preventing it from being readily accessible.
Recent events (3)
  • — F (S) $0
  • — C (S) $3000
  • — Z (S) $3000

1910.176 B

Other-than-serious 1 instance 50 exposed
Issued
Sep 4, 2014
Penalty
Initial $5,000 · Current $1,000 Reduced
29 CFR 1910.176(b): Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.    a. In row 25 of the Green Meadows Building, materials of the top rack of the shelving system were not stored securely and were in danger of falling into an employee work area.
Recent events (3)
  • — F (O) $1000
  • — C (S) $5000
  • — Z (S) $5000

1910.303 G01

Other-than-serious 1 instance 50 exposed
Issued
Sep 4, 2014
Abate by
Feb 11, 2016
Penalty
Initial $3,000 · Current $500 Reduced
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.    a. In the Green Meadows Building near man door 01, sufficient access and working space was not available for the electrical panels.     b. In the Green Meadows Building near dock door 25, sufficient access and working space was not available for the electrical panels.
Recent events (3)
  • — F (O) $500
  • — C (S) $3000
  • — Z (S) $3000

View Volvo Parts North America, INC.'s full OSHA safety record →